Hydride generation in-atomizer collection atomic absorption spectrometry for the determination of antimony in acetic acid leachates from pewter cups.

نویسندگان

  • Morgana B Dessuy
  • Jan Kratzer
  • Maria Goreti R Vale
  • Bernhard Welz
  • Jiří Dědina
چکیده

Antimony is one of the constituents of pewter, an alloy composed of a minimum of 90% tin with the balance being made up with copper, antimony and perhaps some bismuth. A method has been developed to determine Sb in acetic acid leachates from pewter cups. The employed instrumentation, an atomic absorption spectrometer, equipped with a quartz trap-and-atomizer device, is simple and relatively inexpensive with low running costs. Interferences due to the presence of tin and ways to control them were investigated in detail. The applied approach made possible to overcome potentially serious interference of Sn leached from the cup material (which was shown to take place in the atomizer), by a combination of (i) high concentration of HCl, which decreases the efficiency of stannane generation and (ii) in-atomizer collection. The resulting Sn tolerance limit was between 10 and 20 mg L(-1). The advantages of the in-atomizer collection are a lower tin interference in the atomizer, and a much better limit of detection (LOD), which makes possible reducing the atomization interference further by working with more diluted sample solutions. Besides the Sn interference, an interference of an unknown volatile compound transported to the atomizer together with stibine was identified in the measured sample solutions. This interference could be controlled using the analyte addition technique. The applicability of the method was tested on solutions containing a wide range of interferents leached from the pewter cups, obtained at leaching times between 1 and 24h. The LOD in the sample solutions was found to be 0.03 μg L(-1) Sb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interferences in the quartz tube atomizer during arsenic and antimony determination by hydride generation atomic absorption spectrometry

Interferences of some metals in the determination of arsenic by hydride generation atomic absorption spectrometry utilizing a quartz tube atomizer were studied. The atomizers were coated under vacuum with Ni, Au, Pd and Cr. The arsenic signal was almost totally suppressed by all the metal coatings and thus the interferences from metal ions in the determination of arsenic were attributed both to...

متن کامل

Arsenic and antimony determination in refined and unrefined table salts by means of hydride generation atomic absorption spectrometry–comparison of sample decomposition and determination methods

An evaluation was made of different digestion methods for the determination of arsenic and antimony in table salt samples prior to hydride generation atomic absorption spectrometric analysis. Microwave acid digestion, classical wet digestion, dry ashing, and fusion were applied to the decomposition of salt samples and optimum conditions were investigated. Samples were decomposed by changing hea...

متن کامل

Mechanism of volatile hydride formation and their atomization in hydride generation atomic absorption spectrometry.

The mechanism of volatile hydride generation (HG) and the formation of analyte atoms in the quartz cell atomizer used in the determination of hydride-forming elements (As, Bi, Ge, Pb, Sb, Sn, Te etc.) by atomic absorption spectrometry (AAS), have been critically reviewed. The nascent hydrogen mechanism failed to explain hydride generation under different experimental conditions when tetrahydrob...

متن کامل

Flow injection hydride generation electrothermal atomic absorption spectrometry with in-atomizer trapping for the determination of lead in calcium supplements.

Lead hydride was generated from acid solution, containing potassium ferricyanide as an oxidizing agent, by the reaction with alkaline borohydride solution. The effects of reaction conditions (hydrochloric acid, ferricyanide and borohydride concentrations), and the lengths of reaction and stripping coils were studied. The effects of trapping temperature and argon flow rate were also investigated...

متن کامل

Speciation of antimony by preconcentration of Sb(III) and Sb(V) in water samples onto nanometer-size titanium dioxide and selective determination by flow injection-hydride generation-atomic absorption spectrometry.

A novel method for prevention of the oxidation of Sb(III) during sample pretreatment, preconcentration of Sb(III) and Sb(V) with nanometer size titanium dioxide (rutile) and speciation analysis of antimony, has been developed. Antimony(III) could be selectively determined by flow injection-hydride generation-atomic absorption spectrometry, coexisting with Sb(V). Trace Sb(III) and Sb(V) were all...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2011