This paper describes a set of magnetic measurement systems employed in the development of insertion devices at LNLS (Brazilian Synchrotron Light Source). They are: rotating coil (which can also operate as a flip-coil), spatial field mapping using Hall probes and parallel coils (Helmholtz configuration) for magnetic blocks characterization. Although such techniques are well established, strict specifications imposed by the beam dynamics on the magnetic field quality, led to a detailed analysis of the sources of error and their minimization. All three systems have already been tested and showed excellent accuracy and repeatability when compared to typical values found in the scientific literature.
منابع مشابه
The Lnls Booster Synchrotron Dipole Magnets
* [email protected] Abstract The Brazilian Synchrotron Light Laboratory (LNLS) has just constructed and commissioned a 500 MeV booster synchrotron to be used as injector for the 1.37 GeV electron storage ring. The booster has been constructed inside the storage ring, where the constraints in space are very tight. For this reason, the booster dipoles were made as small as possible, i.e., with small cu...
متن کاملSynthesis and characterization of chitosan-magnetic iron nanoparticles
Absorption is a common technology used for water and wastewater treatment since it is often fast and efficient, while costly at the same time. Therefore, the development of low-cost and efficient adsorbents has led to the rapid growth of research interest in this regard. Chitosan is a natural polyaminosaccharide with effective adsorption properties, which is applied to remove various pollutants...
متن کاملSynthesis and Investigation of Structural, Magnetic and Antibacterial Properties of Calcium-Magnesium Ferrite Nanoparticles by Thermal Treatment Method
This paper reports optical, magnetic and antibacterial properties of calcium-magnesium nanostructure which was prepared by a simple thermal treatment method. Calcination was conducted at temperatures 500 K, The influence of calcination temperature on the degree of crystallinity, microstructure, and phase composition was investigated by different characterization techniques, i.e., X-ray diffract...
متن کاملMagnetic Measurement System for Superconductive Coils*
A device for precise magnetic measurements of superconductive coils was designed, built and installed at the synchrotron radiation source ANKA, Forschungszentrum Karlsruhe. Accurate magnetic field measurements are a prerequisite for the characterization and optimization of insertion devices. The new device allows measuring the magnetic field magnitude of test coils with a longitudinal precision...
متن کاملSynthesis and Characterization of Novel Modified and Functionalized Silica Nano-particles for Protein Delivery Applications
In this study, the synthesis, characterization and controlled release behavior of new Hollow Silica Nano particles (HSNPs) and Magnetic Silica Nano Particles (MSNPs) were studied. Magnetic Silica Nano particles (MSNPs), as drug delivery vehicles, were synthesized through the coating of Fe3O4 nano-crystals with silica layers. The HSNPs were obtained by removal of Fe3O4 templates with hydrochlori...
متن کامل