Data for TROTS – The Radiotherapy Optimisation Test Set
نویسندگان
چکیده
The Radiotherapy Optimisation Test Set (TROTS) is an extensive set of problems originating from radiotherapy (radiation therapy) treatment planning. This dataset is created for 2 purposes: (1) to supply a large-scale dense dataset to measure performance and quality of mathematical solvers, and (2) to supply a dataset to investigate the multi-criteria optimisation and decision-making nature of the radiotherapy problem. The dataset contains 120 problems (patients), divided over 6 different treatment protocols/tumour types. Each problem contains numerical data, a configuration for the optimisation problem, and data required to visualise and interpret the results. The data is stored as HDF5 compatible Matlab files, and includes scripts to work with the dataset.
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملبررسی صحیح بودن مقدار اشعه داده شده در پرتودرمانی سرطان پستان با ترمولومینسانس دوزیمتری
In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...
متن کاملEmergency department resource optimisation for improved performance: a review
Emergency departments (EDs) have been becoming increasingly congested due to the combined impacts of growing demand, access block and increased clinical capability of the EDs. This congestion has known to have adverse impacts on the performance of the healthcare services. Attempts to overcome with this challenge have focussed largely on the demand management and the application of system wide p...
متن کاملDesign of Experiments for training metamodels in simulation-based optimisation of manufacturing systems Design of Experiments for training metamodels in simulation-based optimisation of manufacturing systems
In this study, the use of DoE for training metamodels in simulation-based optimisation of manufacturing systems is evaluated. The evaluation is done through a case study of a real manufacturing system. A simulation model of the system exist and the aim is to train an Artificial Neural Network as a metamodel of the system with as high accuracy as possible. Two training data sets generated using ...
متن کاملA Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کامل