Comparison of zero-profile anchored spacer versus plate-cage construct in treatment of cervical spondylosis with regard to clinical outcomes and incidence of major complications: a meta-analysis.
نویسندگان
چکیده
PURPOSE Meta-analysis was conducted to evaluate whether zero-profile anchored spacer (Zero-P) could reduce complication rates, while maintaining similar clinical outcomes compared to plate-cage construct (PCC) in the treatment of cervical spondylosis. METHODS All prospective and retrospective comparative studies published up to May 2015 that compared the clinical outcomes of Zero-P versus PCC in the treatment of cervical spondylosis were acquired by a comprehensive search in PubMed and EMBASE. Exclusion criteria were non-English studies, noncomparative studies, hybrid surgeries, revision surgeries, and surgeries with less than a 12-month follow-up period. The main end points including Japanese Orthopedic Association (JOA) and Neck Disability Index (NDI) scores, cervical lordosis, fusion rate, subsidence, and dysphagia were analyzed. All studies were analyzed with the RevMan 5.2.0 software. Publication biases of main results were examined using Stata 12.0. RESULTS A total of 12 studies were included in the meta-analysis. No statistical difference was observed with regard to preoperative or postoperative JOA and NDI scores, cervical lordosis, and fusion rate. The Zero-P group had a higher subsidence rate than the PCC group (P<0.05, risk difference =0.13, 95% confidence interval [CI] 0.00-0.26). However, the Zero-P group had a significantly lower postoperative dysphagia rate than the PCC group within the first 2 weeks (P<0.05, odds ratio [OR] =0.64, 95% CI 0.45-0.91), at the 6th month [P<0.05, OR =0.20, 95% CI 0.04-0.90], and at the final follow-up time [P<0.05, OR =0.13, 95% CI 0.04-0.45]. CONCLUSION Our meta-analysis suggested that surgical treatments of single or multiple levels of cervical spondylosis using Zero-P and PCC were similar in terms of JOA score, NDI score, cervical lordosis, and fusion rate. Although the Zero-P group had a higher subsidence rate than the PCC group, Zero-P had a lower postoperative dysphagia rate and might have a lower adjacent-level ossification rate.
منابع مشابه
The new Zero-P implant can effectively reduce the risk of postoperative dysphagia and complications compared with the traditional anterior cage and plate: a systematic review and meta-analysis
BACKGROUND The low-profile angle-stable spacer Zero-P is a new kind of cervical fusion system that is claimed to limit the potential drawbacks and complications. The purpose of this meta-analysis was to compare the clinical and radiological results of the new Zero-P implant with those of the traditional anterior cage and plate in the treatment of symptomatic cervical spondylosis, and provides c...
متن کاملMeta-Analysis Comparing Zero-Profile Spacer and Anterior Plate in Anterior Cervical Fusion
BACKGROUND Anterior plate fusion is an effective procedure for the treatment of cervical spinal diseases but is accompanied by a high incidence of postoperative dysphagia. A zero profile (Zero-P) spacer is increasingly being used to reduce postoperative dysphagia and other potential complications associated with surgical intervention. Studies comparing the Zero-P spacer and anterior plate have ...
متن کاملZero-profile implant versus conventional cage-plate implant in anterior cervical discectomy and fusion for the treatment of degenerative cervical spondylosis: a meta-analysis
BACKGROUND Zero-profile implant has become more and more popular in anterior cervical discectomy and fusion (ACDF) for the treatment of degenerative cervical spondylosis. However, there was no enough evidence judging its efficiency and safety. The aim of this analysis was to evaluate the efficacy and safety of Zero-profile implant compared with conventional cage-plate (CCP) in ACDF. METHODS A...
متن کاملComparison of anterior cervical discectomy and fusion with the zero-profile implant and cage-plate implant in treating two-level degenerative cervical spondylosis
Previous studies based on small sample sizes have reported the application of the Zero-P implant (Zero-P, Synthes GmbH, Switzerland) in single anterior cervical discectomy and fusion (ACDF) surgery with excellent outcomes. However, the safety and effectiveness of two-level ACDF with Zero-P implant still remains controversial. A retrospective study was conducted to compare the clinical outcomes ...
متن کاملComparison of the clinical effects of zero-profile anchored spacer (ROI-C) and conventional cage-plate construct for the treatment of noncontiguous bilevel of cervical degenerative disc disease (CDDD)
Comparing the clinical and radiographic outcomes in anterior cervical discectomy and fusion (ACDF) using a zero-profile anchored spacer (ROI-C) or a conventional cage-plate construct (CPC) for treating noncontiguous bilevel of cervical degenerative disc disease (CDDD).Overall, 46 patients with 2 noncontiguous segments of CDDD, treated with ACDF from January 2011 to October 2015, were included i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Therapeutics and clinical risk management
دوره 11 شماره
صفحات -
تاریخ انتشار 2015