Preparation and characterization of standard reference material 1849 infant/adult nutritional formula.

نویسندگان

  • Katherine E Sharpless
  • Richard M Lindstrom
  • Bryant C Nelson
  • Karen W Phinney
  • Catherine A Rimmer
  • Lane C Sander
  • Michele M Schantz
  • Rabia O Spatz
  • Jeanice Brown Thomas
  • Gregory C Turk
  • Stephen A Wise
  • Laura J Wood
  • James H Yen
چکیده

Standard Reference Material (SRM) 1849 Infant/Adult Nutritional Formula has been issued by the National Institute of Standards and Technology (NIST) as a replacement for SRM 1846 Infant Formula, issued in 1996. Extraction characteristics of SRM 1846 have changed over time, as have NIST's analytical capabilities. While certified mass fraction values were provided for five constituents in SRM 1846 (four vitamins plus iodine), certified mass fraction values for 43 constituents are provided in SRM 1849 (fatty acids, elements, and vitamins) and reference mass fraction values are provided for an additional 43 constituents including amino acids and nucleotides, making it the most extensively characterized food-matrix SRM available from NIST.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of ultra-high-performance liquid chromatography/tandem mass spectrometry for the measurement of vitamin D in infant formula and adult/pediatric nutritional formula: First Action 2011.11.

In an effort to measure vitamin D, ultra-high-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) was applied to samples. The use of UHPLC-MS/MS decreased the run time by 50%. The UHPLC-MS/MS achieved equal or better separation efficiency with complex food matrixes compared to HPLC-MS/MS. It was also observed that under the optimized conditions of UHPLC, all previtamin...

متن کامل

Determination of Total Iodine in Infant Formula and Adult/ Pediatric Nutritional Formula by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Collaborative Study, Final Action 2012.15.

A collaborative study was conducted to determine total iodine in infant formula and adult/pediatric nutritional formula by inductively coupled plasma-MS (ICP-MS) using AOAC First Action Official Method(SM) 2012.15. The purpose of this study was to evaluate the method's intralaboratory and interlaboratory performance and submit the results to AOAC INTERNATIONAL for adoption as a Final Action Off...

متن کامل

Determination of Microelements in Human Milk and Infant Formula Without Digestion by ICP-OES.

The concentrations of zinc (Zn), iron (Fe) and copper (Cu) in both human milk and infant formula were determined using a new sample preparation method, by inductively coupled plasma - optical emission spectometry (ICP-OES) and flame atomic absorption spectrometry (FAAS). Human milk samples were diluted in ultrapure water. The infant formula of powder samples (suitable for an infant 1-6 months o...

متن کامل

Application of inductively coupled plasma/mass spectrometry for the measurement of chromium, selenium, and molybdenum in infant formula and adult nutritional products: First Action 2011.19.

An inductively coupled plasma/MS method was developed for the simultaneous determination of Cr, Se, and Mo in infant formula and other nutritional products. All samples were digested using a closed vessel microwave oven system, together with Ni and Te internal standards. The practical quantitation limits for Cr, Se, and Mo were 0.4, 0.2, and 0.4 ng/mL, respectively; dilution factors were 250 fo...

متن کامل

Simultaneous Determination of Vitamin A and E in Infant Formula by Rapid Extraction and HPLC with Photodiode Array Detection

Rapid and simple method was developed for simultaneous determination of vitamins A and E contents in infant formula. Vitamins A and E were extracted by PDA-HPLC with reversed phase column using organic solvent, and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with results of Food Standards Codex and AOAC method for evaluation of developed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 93 4  شماره 

صفحات  -

تاریخ انتشار 2010