Two Dimensional Laser Scanner for Blood Perfusion Imaging Through Curved Sections of Human Forearm
نویسندگان
چکیده
Blood flow in microcirculation has found vital role in maintenance of body temperature. Its measurement is vital in the field of skin-vessel reactivity, ageing of skin, micro vascular repair of the ulnar artery and wound healing in association with total elbow replacement. The existing techniques for blood flow measurements like Electromagnetic blood flow measurement, Thermal convection method, Dual radiographic method, Ultrasonic Blood flow measurement and NMR method are not found suitable for measurement of blood flow in microcirculation due to their large size, complexity, invasive nature of measuring element and possibility of radiation exposure to the patient. Hence, a new technology is developed for micro vascular blood flow or velocity measurement using He-Ne laser of wavelength 632.8nm.
منابع مشابه
Methodological concerns with laser speckle contrast imaging in clinical evaluation of microcirculation
BACKGROUND Laser Speckle Contrast Imaging (LSCI) is a non-invasive and fast technique for measuring microvascular blood flow that recently has found clinical use for burn assessment and evaluation of flaps. Tissue motion caused by for example breathing or patient movements may however affect the measurements in these clinical applications, as may distance between the camera and the skin and tis...
متن کاملLaser-Doppler imaging of forearm skin: perfusion features and dependence of the biological zero on heat-induced hyperemia.
BACKGROUND: When measuring skin blood perfusion with laser-Doppler methods in a limb, a non-zero perfusion is sometimes registered even when the arterial inflow to, and venous outflow from the site of measurement is arrested using proximal cuff compression pressures well in excess of systolic blood pressure. This residual signal, known as the biological zero (BZ)1-7, is present to some extent w...
متن کاملFeasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion MRI at 3 Tesla using local RF Shimming with dual-source RF transmission
Background Three-dimensional myocardial perfusion MRI offers better myocardial coverage than conventionally used two-dimensional methods. bSSFP three-dimensional myocardial perfusion MRI at 3 Tesla potentially offers further improvement of signal characteristics and may enhance the use of three-dimensional myocardial perfusion MRI for clinical application. Methods Twenty-five healthy volunteers...
متن کاملOptimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition
Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...
متن کاملSemi-Analytical Solution for Free Vibration Analysis of Thick Laminated Curved Panels with Power-Law Distribution FG Layers and Finite Length Via Two-Dimensional GDQ Method
This paper deals with free vibration analysis of thick Laminated curved panels with finite length, based on the three-dimensional elasticity theory. Because of using two-dimensional generalized differential quadrature method, the present approach makes possible vibration analysis of cylindrical panels with two opposite axial edges simply supported and arbitrary boundary conditions including Fre...
متن کامل