― ― 12 Detection of Atrial Fibrillation during Pulpal Blood Flow Assessment using

نویسندگان

  • Chan‒Hyun Lee
  • Sunil Kim
  • Dohyun Kim
  • Euiseong Kim
  • Manahil. S. Ali
  • Motoki Okamoto
  • Shungo Komichi
  • Masakatsu Watanabe
  • Yoshihiro Ito
  • Yusuke Takahashi
  • Mikako Hayashi
چکیده

Case Report: This report describes the case of a 52‒year‒old male patient who exhibited suspicious pulsation patterns during pulpal blood flow assessment using Doppler ultrasound. Initially, he was not aware of his cardiovascular problem;however, after referral to a medical clinic, he was diagnosed with atrial fibrillation. The patient was injured in a motor vehicle accident and referred to our clinic for management of multiple traumatized teeth. On clinical examination, several teeth exhibited negative responses to cold and electrical sensibility tests. To make an accurate diagnosis, pulpal blood flow assessment using a Doppler ultrasound device was performed. During the tests, irregular pulsation patterns were detected, indicating the possibility of a cardiovascular problem. As he denied any history of cardiovascular problems, he was recommended to visit a medical doctor for further evaluation. The following day, he visited a medical clinic, and a 12‒lead electrocardiogram was performed. He was ultimately diagnosed with atrial fibrillation with idioventricular rhythm, and was started on anti‒coagulant medication for prevention of thrombogenesis, which is a possible complication of atrial fibrillation. As presented in this case, Doppler ultrasound can provide useful information, not only about blood flow in the dental pulp, but also about an individual’s pulsation rhythm. When a patient presents irregular pulsation patterns in certain situations, the possibility of cardiovascular problems should be considered and appropriate referral to a medical doctor should be made.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of acute atrial fibrillation on phasic coronary blood flow pattern and flow reserve in humans.

AIMS To assess the effect of experimentally induced atrial fibrillation on coronary flow in humans. METHODS AND RESULTS In 16 patients (10 men, mean age 43+/-13 years) with normal coronary vessels, baseline and hyperaemic blood pressure and Doppler phasic coronary flow velocity were measured, using a 0.014 inch intracoronary Doppler flow wire, during sinus rhythm, experimentally induced atria...

متن کامل

Assessment of P-wave indices as atrial fibrillation predictors in psoriasis patients

Background: Psoriasis is a prevalent chronic T cell mediated inflammatory skin disorder. Recent studies have reported an increase in the incidence of arrhythmia in psoriasis patients who run an excessive risk of metabolic syndrome and cardiovascular diseases. P-wave dispersion (PWD) and duration are important electrocardiographic (ECG) markers employed to anticipate the risk of atrial arrhythmi...

متن کامل

Alteration of peripheral vasodilatory reserve capacity after cardioversion of atrial fibrillation.

In atrial fibrillation, exercise capacity is often reduced. This is usually ascribed to a decreased cardiac output as compared with sinus rhythm. Very few studies, however, have focused on changes in the peripheral blood flow during atrial fibrillation as a potential mechanism for exercise limitation. The aim of the present study was to determine the effect of conversion of atrial fibrillation ...

متن کامل

Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation

Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from...

متن کامل

Incidence of Atrial Fibrillation after Coronary Artery Bypass Graft Surgery and Its Risk Factors in Shiraz, Iran during 2017-18

Background and Objectives: Atrial fibrillation is one of the most common disorientations after coronary artery bypass graft surgery and can affect the chance of survival in the first year after surgery. The present study aimed to determine the incidence of atrial fibrillation after coronary artery bypass graft surgery and its risk factors.   Methods: This cross-sectional study was performed on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017