Noninvasive in vivo assessment of soft contact lens type on tear film surface quality.
نویسندگان
چکیده
PURPOSE To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types. METHODS Thirteen subjects wearing four different types of daily soft contact lenses participated in the study. Dynamic area high-speed videokeratoscopy (HSV) and lateral shearing interferometry (LSI) were used to quantitatively assess TFSQ in natural blinking conditions in the morning soon after lens insertion and in the afternoon following 8 hours of lens wear. RESULTS All considered contact lenses caused a significant reduction in TFSQ compared with bare eye measures. Significant differences (P < 0.05) in the average TFSQ were also observed between all contact lens materials in LSI measurements and in the majority of dynamic area HSV measurements. The potential relationship between the contact lens parameters and the observed decline in the prelens TFSQ was explored. CONCLUSIONS Noninvasive techniques of tear film surface assessment have the potential to discriminate contact lens type/material on eye. LSI was found to more effectively perform this discrimination than the dynamic area HSV technique.
منابع مشابه
Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers.
Purpose To investigate the correlation between the changes in the ocular surface temperature (OST) and tear film stability over soft contact lenses (SCLs). Methods We enrolled 20 eyes of 20 normal SCL wearers (20 men; 24.4 ± 4.1 years). We used four different daily disposable SCLs: one silicone hydrogel lens (delefilcon A) and three hydrogel lenses (etafilcon A with polyvinylpyrrolidone [PVP]...
متن کاملTear Film Evaluation in Contact Lens Wearers and Non Wearers
Background: Dry eye symptoms are more frequent in contact lens wearers than in non wearers. Dry eye is considered relatively common in contact lens wearers than non-wearers. However, there was no any report in our clinical setting that compared and addressed the issue related to dry eye and its symptom in contact lens wearers. The present study was conducted to compare pre-ocular tear film in c...
متن کاملTear film surface quality with rigid and soft contact lenses.
OBJECTIVES The aim of this study was to measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hrs) use of rigid and soft contact lenses. METHODS A group of 14 subjects wore 3 different types of contact lenses on 3 different nonconsecutive days (order randomized) in 1 eye only. The subjects were screened to exclude those with dry eye. The lense...
متن کاملThe Mechanics of a Hydrogel Contact Lens on the Human Eye with a Lubricating Tear Layer
The mechanics governing the fit of a soft contact lens on the eye are examined through the development of a finite element analysis model. A linearly elastic lens is placed on a rigid eye with a lubricating viscoelastic tear layer. The mechanics of fit are described in terms of the pressure distribution through the tear layer, the contact pressure at the lens/tear interface, the tear film thick...
متن کاملContinuing education CET
● Tear film assessment should be undertaken with minimal invasion of the structure – non-invasive techniques should be used whenever possible ● Assessment must be made both prior to and during contact lens wear. Tear film quality should be assessed both with the lens in situ and without the lens ● Use of the Tearscope in clinical practice allows a more detailed examination of the tears to be un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 53 1 شماره
صفحات -
تاریخ انتشار 2012