Diffusion Monte - Carlo method : tests by the simulations of 2 D electron in magnetic field and 2 D fermions - anyons in parabolic well
نویسنده
چکیده
We propose a new Complex Diffusion Monte Carlo (CDMC) method for the simulation of quantum systems with complex wave function. In CDMC the modulus and phase of wave function are simulated both in contrast to other methods. We successfully test CDMC by the simulation of the ground state for 2D electron in magnetic field and 2D fermionsanyons in parabolic well.
منابع مشابه
Complex diffusion Monte - Carlo method : test by the simulation of the 2 D fermions
On the base of the diffusion Monte-Carlo method we develop the method allowing to simulate the quantum systems with complex wave function. The method is exact and there are no approximations on the simulations of the module and the phase of the system’s wave function. In our method averaged value of any quantity have no direct contribution from the phase of distribution function but only from t...
متن کاملEffect of uniform magnetic field on dose distribution in the breast radiotherapy
Background: To reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. Materials and Methods: Monte Carlo simulations were performed with GEANT4, irradiating humanoid phantoms in a magnetic field. To reconstruct phantoms, computed tomography (CT) data slices of four patients were used for the Monte Car...
متن کاملEvaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study
Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...
متن کاملAnalytical investigation of the practical range and deflection of megavoltage electron beam in the water phantom with the presence of magnetic field
Introduction: Integrated radiation therapy - MRI systems are capable of delivering high doses to the target tissues near sensitive organs and achieve better therapeutic results; however, the Applied magnetic fields for imaging, can influence the charged path, change the penetration depth and deflect the particles, laterally, leading to dose distribution variations. Therefore, i...
متن کاملAn assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method
Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...
متن کامل