Fenestrations enhance tear mixing under silicone-hydrogel contact lenses.
نویسندگان
چکیده
PURPOSE Extended wear of conventional hydrogel soft contact lenses (SCLs) is associated with adverse ocular responses. Some of these ocular events are thought to result from inadequate tear mixing in the postlens tear film (PoLTF). Therefore, strategies to increase tear mixing may improve the safety of extended-wear SCLs. Recently, it has been suggested that placing fenestrations in soft lenses increases tear mixing. In the present study, hydrodynamic modeling and tear-mixing measurements were used to explore the effects of fenestrations on tear exchange under an SCL. METHODS Tear mixing, expressed as the time to deplete 95% of fluorescent dye from the PoTLF (T(95)), was measured in 20 subjects fitted with two pairs of silicone hydrogel SCLs. The lenses were identical except that one pair was fenestrated (F) with 40 holes each 100 microm in diameter. The effect of fenestrations on improving tear mixing is explained and enhancement of tear mixing is predicted, with the use of hydrodynamic modeling. RESULTS T(95) estimates were significantly lower (P < 0.001) in the F (mean T(95) = 18.3 minutes) lenses compared with the standard unfenestrated (S-uF) (mean T(95) = 22.6 minutes) lenses (DeltaT(95) = 4.3 minutes, 95% CI = 2.5-6.2) and were in general agreement with the proposed mixing model. Optimization of tear mixing can be achieved by selectively placing fenestrations in the pooling regions before the thinnest regions. The model predictions were sensitive to the distribution of tear-film thickness under the lens. CONCLUSIONS Fenestrations improve tear-mixing efficiency. Accurate prediction of the effects of lens parameters on tear mixing, however, demands quantitative measurement of the postlens distribution of tear-film thickness.
منابع مشابه
Tear exchange under hydrogel contact lenses: methodological considerations.
PURPOSE To characterize hydrogel lens tear exchange and to apply an optimized method to compare tear exchange of a marketed hydrogel lens to that measured with a prototype silicone hydrogel lens. METHODS Fluorophotometry and a nonpenetrating tracer (70-kDa FITC-dextran) were used with a single extended-wear soft contact lens (EWSCL) material on 11 subjects to characterize tear-exchange kineti...
متن کاملAssociation Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers.
Purpose To investigate the correlation between the changes in the ocular surface temperature (OST) and tear film stability over soft contact lenses (SCLs). Methods We enrolled 20 eyes of 20 normal SCL wearers (20 men; 24.4 ± 4.1 years). We used four different daily disposable SCLs: one silicone hydrogel lens (delefilcon A) and three hydrogel lenses (etafilcon A with polyvinylpyrrolidone [PVP]...
متن کاملPredicting success with silicone-hydrogel contact lenses in new wearers.
PURPOSE to evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not. METHODS Non-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyp...
متن کاملInfluence of Tear Protein Deposition on the Oxygen Permeability of Soft Contact Lenses
Purpose. To investigate the effect of tear protein deposition on the change in oxygen permeability (Dk) of soft contact lenses (SCL). Methods. Three hydrogel lenses (polymacon, nelfilcon A, and etafilcon A) and two silicon hydrogel lenses (lotrafilcon A and balafilcon A) were investigated. Etafilcon A lenses were incubated in artificial tear solution for 1, 6, 12, and 48 h, whereas the other SC...
متن کاملTear film inflammatory mediators during continuous wear of contact lenses and corneal refractive therapy.
OBJECTIVES To study changes in tear film inflammatory mediators following continuous wear of silicone-hydrogel lenses and corneal refractive therapy with reverse geometry contact lenses. DESIGN A prospective, case-control study. METHODS Twenty-eight subjects had worn silicone-hydrogel lenses on a 30-night continuous wear basis. Thirty-two subjects had worn corneal refractive therapy lenses ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 44 1 شماره
صفحات -
تاریخ انتشار 2003