Heat Loss Test and Estimate for the Large-scale Floating Roof Tank
نویسندگان
چکیده
The heat loss and surface temperature of the top surface and sidewall of large-scale floating roof tank is tested by the heat flow meter and surface temperature method. Based on the test data, the heat loss from the top surface is about twice more than that of the sidewall which means the top surface is the weakest insulation part of the floating roof tank. On the surface, the heat loss profile is in accord with the surface temperature distribution. Special attention is given on the calculation of thermal conductivity for the top surface and sidewall which finally deduced the total heat transfer coefficient of large floating roof tank. Moreover, the heat loss of floating roof tank in different working conditions is predicted. According to the calculation results, the level of 6m is regarded as a critical level determining the heat loss. And the centralization storage of oil is a more energy conservation storage pattern.
منابع مشابه
Stress Patterns in Single Deck Floating Roofs Subjected to Ground Motion Accelerations
This paper investigates the induced stresses in circular single deck roofs floating on seismically excited storage tanks. Equations of motion are derived using variational principle. Response of deck floating roofs is evaluated for two different classes of ground motions; near-source and long-period far-field records. Besides time histories and frequency contents for a specific tank, peak value...
متن کاملEffect of Flexural and Membrane Stiffness on the Analysis of Floating Roofs
With the aim of extending the use of integrated variational principles on fluid and deckplate to the large deflection analysis of floating roofs, this paper investigates the significance of theflexural and membrane components in the formulations of the deck plate. Applying integratedvariational principles on deck plate and fluid facilitate the treatment of the compatibility ofdeformation betwee...
متن کاملProtection of Floating Roof Petroleum Storage Tanks against Lightning Strokes
The subject of petroleum storage tank fires has gained a great deal of attention due to the high cost of petroleum, and the consequent disruption of petroleum production; therefore, much of the current research has focused on petroleum storage tank fires. Also, the number of petroleum tank fires is oscillating between 15 and 20 fires per year. About 33% of all tank fires are attributed to light...
متن کاملارزیابی احتمال وقوع رهایش مواد مایع نفتی ازمخزن سقف شناور پالایشگاه نفت به روش آنالیز فازی درخت خطا(FFTA)
Background and aims: Process industries are known to be hazardous industries. Chemical Industrial process involves several processes such as drilling and production, storage, transportation, and refining. These activities are different in nature. Also, they are different in job Risks. One of the main and dangerous sections of the process is oil reservoir. Therefore, this study aimed to identify...
متن کاملStudy of thermal performance of building roofs in the city of Tehran
The design of a building can provide the highest thermal comfort in the interior without any mechanical equipment and save energy to a large extent. The roof of a building is an important part for thermal loss. This research studies the thermal performance of 14 conventional roof structures in Tehran city by using designbuilder 4.5. It is found that the polystyrene block performs best compared ...