Washing plastic spacers in household detergent reduces electrostatic charge and greatly improves delivery.

نویسندگان

  • F Piérart
  • J H Wildhaber
  • I Vrancken
  • S G Devadason
  • P N Le Souëf
چکیده

Ionic detergents reduce electrostatic charge on plastic spacers, thereby improving in vitro drug delivery. The aim of this study was to gain practical information on the use of detergents and to evaluate the relevance of this information on in vivo drug deposition. Measurement of electrostatic charge and salbutamol particle size distribution was carried out on detergent-coated and noncoated plastic spacers. The efficiency of four household detergents was compared, and the influence of dilution and the duration of the antistatic effect were studied. In addition, the level of radiolabelled salbutamol deposition in the lungs of eight healthy adults was compared after inhalation through a new versus a detergent-coated spacer. In vitro, all tested detergents reduced the electrostatic charge on the spacer surface. This resulted in a mean increase of 37.4% (range 33.5-41.2) in small particle (<6.8 microm) salbutamol output compared with water-rinsed/drip-dried spacers. Dilution had no influence on the results and the effect lasted for at least four weeks. In vivo, the mean lung deposition of radiolabelled salbutamol in healthy subjects was 45.6% (range 43.4-49.5) through a detergent-coated spacer compared to 11.5% (range 7.6-17.9) through a static spacer (p<0.001). In conclusion, household detergents offer a simple and practical solution to the problem of static on plastic spacers and significantly improve both in vitro and in vivo delivery of salbutamol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrostatic charge on a plastic spacer device influences the delivery of salbutamol.

The aim of this study was to determine whether electrostatic charge on a plastic spacer decreases the delivery of salbutamol from a pressurized metered-dose inhaler (pMDI) and, if so, to find an optimal and practical treatment to remove the charge. Ten single actuations from a salbutamol pMDI were drawn through different Volumatic spacers at a constant flow of 60 L.min-1. The efficacies of diff...

متن کامل

Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants.

BACKGROUND A study was undertaken to determine the influences of electrostatic charge, flow, delay, and multiple actuations on the in vitro delivery of salbutamol generated by a pressurised metered dose inhaler (pMDI) from small volume spacers used in infants. METHODS Ten actuations from a salbutamol pMDI were drawn at different flow rates after either single or multiple actuations, with or w...

متن کامل

Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.

AIM The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery comp...

متن کامل

Aerosol delivery from spacers in wheezy infants: a daily life study.

The aims of this study were to assess and compare dose delivery and dose variability of pressurized metered dose inhalers (pMDI)/spacers in wheezy infants in daily life and to investigate factors influencing aerosol delivery. In an open randomized crossover study in 25 wheezy infants aged 5-26 months, a metal spacer (Nebuchamber), a detergent coated (DC) and a non-detergent coated (nonDC) plast...

متن کامل

The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients.

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 1999