Interest of 3D Fat-Saturated T1-Weighted Magnetic Resonance Imaging for the Assessment of Cervical Artery Dissection

نویسندگان

  • Yasser Bencheikh
  • Pola Kulczycka
  • Francesco Macri
  • Domitille Millon
  • Joel Greffier
  • Jean Paul Beregi
  • Ahmed Larbi
چکیده

A 43–years–old woman without any medical history or particular treatment consulted the emergency room for fluctuant headache, developing for five days and resistant to usual treatment. The headache was associated with hypoesthesia of the left part of the face with ptosis. Clinical examination found a slight hypoesthesia in V2 and V3 territories and a Bernard-Horner’s syndrome. Brain magnetic resonance imaging (MRI) showed no brain parenchymal abnormality, especially on diffusion-weighted imaging. Cervical vessels imaging with axial fat suppressed spin echo T1-weighted sequence showed a pre occlusive dissection of petrous segment of the left carotid artery. Study of the cervical portion was suboptimal due to the magnetic susceptibility artifact of a dental implant (Figure 1A). A complementary 3D volumetric fat suppressed spin echo T1-weighted sequence was realized and allowed to partially overcome this artifact and to bring out the extension of this dissection to the cervical part of the carotid artery (Figure 1B, arrow). MR angiography with injection of gadolinium chelates confirmed a tapered stenosis of the left carotid artery (Figure 1C, arrows). The patient was treated with efficient anticoagulant therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cervial artery dissection: value of 3D high resolution vessel wall magnetic resonance imaging for diagnosis and follow-up

Background Cervical artery dissection (CD) is an important cause of stroke in young and middle-aged patients. Sampling perfection with application-optimised contrast using different flip angle evolutions (SPACE) sequence can provide fast 3D isotropic T1 FS images, with very good dark blood contrast. This study aims to demonstrate the value of a 3D fat-saturated SPACE for the diagnosis and follo...

متن کامل

Neurological picture. "Puppy sign" indicating bilateral dissection of internal carotid artery.

Segregation of a missense mutation in the amyloid precursor protein gene with familial Alzheimer's disease. Lewy bodies in Alzheimer's disease: a neuropathological review of 145 cases using alpha-synuclein immunohistochemistry. Lewy body pathology in familial Alzheimer's disease: evidence for disease and mutation-specific pathologic phenotype. Lewy body pathology in late-onset familial Alzheime...

متن کامل

I-41: Imaging Strategy for Diagnosis of Adnexal Masses Including US,CT Scan and MRI

Adnexal masses are spectrum of diseases from benign non neoplastic and neoplastic masses to malignant neoplasms. Endovaginal ultrasonography (US) is the fisrt and invaluable modality for assessment of adnexal masses because it is available and has a high negative predictive value. Important morphologic features are solid (vascularized) tissue, vascular and thick septations, and papillary projec...

متن کامل

Spontaneous vertebral artery dissection with multiple supratentorial and infratentorial acute infarcts in the posterior circulation Case report

The article represents a case of a young patient with atypical clinical and paraclinical presentation of vertebral artery dissection by multiple cerebral infarcts, localized at the supratentorial and infratentorial levels in the posterior circulation. A case of a 21-year-old man, without a history of trauma in the cervical area or at the cranial level, without recent chiropractic maneuvers or p...

متن کامل

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016