Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine.

نویسندگان

  • X Monnet
  • L Guérin
  • M Jozwiak
  • A Bataille
  • F Julien
  • C Richard
  • J-L Teboul
چکیده

BACKGROUND In patients receiving an infusion of norepinephrine, the relationship between the amplitude of the oximeter plethysmographic waveform and stroke volume may be variable and quality of the waveform might be reduced, compared with patients not receiving norepinephrine. We assessed the reliability of the pleth variability index (PVI), an automatic measurement of the respiratory variation of the plethysmographic waveform, for predicting fluid responsiveness in patients receiving norepinephrine infusions. METHODS We measured the response of cardiac index (transpulmonary thermodilution) to i.v. fluid administration in 42 critically ill patients receiving norepinephrine. Patients with arrhythmias, spontaneous breathing, tidal volume <8 ml kg(-1), and respiratory system compliance <30 ml cm H(2)O(-1) were excluded. Before fluid administration, we recorded the arterial pulse pressure variation (PPV) and pulse contour analysis-derived stroke volume variation (SVV, PiCCO2) and PVI (Masimo Radical-7). RESULTS In seven patients, the plethysmographic signal could not be obtained. Among the 35 remaining patients [mean SAPS II score=77 (sd=17)], i.v. fluid increased cardiac index ≥15% in 15 'responders'. A baseline PVI ≥16% predicted fluid responsiveness with a sensitivity of 47 (inter-quartile range=21-73)% and a specificity of 90 (68-99)%. The area under the receiver operating characteristic curve was significantly lower for PVI [0.68 (0.09)] than for PPV and SVV [0.93 (0.06) and 0.89 (0.07), respectively]. Considering all pairs of measurements, PVI was correlated with PPV (r(2)=0.27). The fluid-induced changes in PVI and PPV were not significantly correlated. CONCLUSIONS PVI was less reliable than PPV and SVV for predicting fluid responsiveness in critically ill patients receiving norepinephrine. In addition, PVI could not be measured in a significant proportion of patients. This suggests that PVI is not useful in patients receiving norepinephrine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pleth Variability Index predicts fluid responsiveness in critically ill patients

OBJECTIVE To investigate whether the pleth variability index, a noninvasive and continuous tool, can predict fluid responsiveness in mechanically ventilated patients with circulatory insufficiency. DESIGN Prospective study. SETTING Surgical intensive care unit of a university hospital. PATIENTS Forty mechanically ventilated patients with circulatory insufficiency in whom volume expansion ...

متن کامل

Pleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery.

BACKGROUND Fluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oxim...

متن کامل

Non-invasive prediction of fluid responsiveness in infants using pleth variability index.

This prospective study assessed whether respiratory variations in velocity time integral, peak blood flow velocity and non-invasive pleth variability index are useful measurements in infants undergoing congenital heart surgery and determined threshold values that may help guide fluid administration. In 27 infants receiving mechanical ventilation, of mean (SD) weight 10.4 (6.3) kg, 13 increased ...

متن کامل

Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients

INTRODUCTION Pleth Variability Index (PVI) is an automated and continuous calculation of respiratory variations in the perfusion index. PVI correlates well with respiratory variations in pulse pressure (ΔPP) and is able to predict fluid responsiveness in the operating room. ICU patients may receive vasopressive drugs, which modify vascular tone and could affect PVI assessment. We hypothesized t...

متن کامل

Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 110 2  شماره 

صفحات  -

تاریخ انتشار 2013