Investigation of the Usage of Palm Oils with the Aim of Insulation in High Voltage Power System Equipments
نویسنده
چکیده
Original scientific paper Power system equipment have conventionally used mineral oil for insulation and cooling. The preferable alloy material has to be generated with good chemical and electrical features. However, recent case has indicated the shortcomings of these fluids where they have poor characteristics particularly at fire and flash point and most significantly poor dielectric malfunction voltage. The most critical of these deficiencies is the disability to meet up with the environmental and health laws. Further, they are not organic and hence not biodegradable. In this study, natural palm oil and its derivatives have been studied in attempt to discover an environmental friendly insulating fluid. Patterns such as crude and refined palm oils were chemically and electrically tested and comparisons were made with the mineral oil. Electrical tests such as the malfunction voltage, power factor and resistivity were pursued. Besides that, chemical characteristics such as water content, kinematic viscosity, moisture content of the alloy, flash point, density, pour point, corrosion, neutralization value and dissolution of gases were also being investigated. Results from the test laboratory studies have indicated that the natural palm oil has preferable chemical and electrical features as compared to the existing mineral oil for power system equipment insulation.
منابع مشابه
Fuzzy Logic Based Life Estimation of PWM Driven Induction Motors
Pulse-width modulated (PWM) adjustable frequency drives (AFDs) are extensively used in industries for control of induction motors. It has led to significant advantages in terms of the performance, size, and efficiency but the output voltage waveform no longer remains sinusoidal. Hence, overshoots, high rate of rise, harmonics and transients are observed in the voltage wave. They increase voltag...
متن کاملInvestigation on Thermal Aging of Ester from Palm Oil and Kraft Paper Composite Insulation System for High Voltage Transformer
Mineral oil is widely being used as insulation for high voltage equipments such as transformer due to its excellent dielectric properties. Recently, due to environment consideration and the long term availability, organic liquid insulations from plantations are being introduced. However, the performance of such insulations in composite with paper should be investigated in order to maintain the ...
متن کاملPartial Discharge in High Voltage Insulating Materials
High voltage transmission has been chosen in electric power system due to its capability to transfer a large amount of electric power. Several key equipments such as generator, transformer, GIS, cable and insulator play important role in determining the reliability of the power system. The high voltage equipments in general contain gas, liquid or solid insulation. Defects and a particular condi...
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملTransient Overvoltages in Power System
There are many reasons for over voltages in power system. The overvoltage causes number of effect in the power system. It may cause insulation failure of the equipments, malfunction of the equipments. Overvoltage can cause damage to components connected to the power supply and lead to insulation failure, damage to electronic components, heating, flashovers, etc. Over voltages occur in a system ...
متن کامل