Position and flux stabilization of X-ray beams produced by double-crystal monochromators for EXAFS scans at the titanium K-edge.
نویسندگان
چکیده
The simultaneous and active feedback stabilization of X-ray beam position and monochromatic beam flux during EXAFS scans at the titanium K-edge as produced by a double-crystal monochromator beamline is reported. The feedback is generated using two independent feedback loops using separate beam flux and position measurements. The flux is stabilized using a fast extremum-searching algorithm that is insensitive to changes in the synchrotron ring current and energy-dependent monochromator output. Corrections of beam height are made using an innovative transmissive beam position monitor instrument. The efficacy of the feedback stabilization method is demonstrated by comparing the measurements of EXAFS spectra on inhomogeneous diluted Ti-containing samples with and without feedback applied.
منابع مشابه
Biological XAFS at the BioCAT Undulator Beamline 18ID at the APS
The Biophysics Collaborative Access Team (BioCAT) undulator beam line at the Advanced Photon Source, Argonne, IL is a user facility devoted to the study of partially ordered and disordered biological materials by X-ray scattering, diffraction and absorption spectroscopy. Two sagital focussing, double-crystal (Si(111) and Si(400)) monochromators and a 1 mmirror provide monochromatic, horizontall...
متن کاملRotation of X-ray polarization in the glitches of a silicon crystal monochromator
EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the 'glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normaliz...
متن کاملDiamond Monochromator for High Heat Flux Synchrotron X-ray Beams
2 Single crystal silicon has been the material of choice for x-ray monochromators for the past several decades. However, the need for suitable monochromators to handle the high heat load of the next generation synchrotron x-ray beams on the one hand and the rapid and on-going advances in synthetic diamond technology on the other make a compelling case for the consideration of a diamond monochro...
متن کاملتحلیل پراکندگی پرتوهای X تشدید یافته در لبه K ی Mn در Nd./5Sr./5MnO3
Studies of phenomena such as charge, orbital and spin ordering in manganite has attracted much interest in recent years. These studies have been possible from an experimental point of view by the third generation synchrotron sources. X-ray with high flux density, tunable energy and polarization can be produced in synchrotron sources. Experiments have shown a resonant in peak intensity originat...
متن کاملMonochromator-induced glitches in EXAFS data II. Test of the model for a pinhole sample
Monochromator-induced glitches m the extended X-ray absorption fine structure (EXAFS) are studied using a pinhole sample . We have collected more detailed beam-profile data that enabled us to do a better simulation of the glitch shape. Applying the model we developed earlier, we obtain excellent agreement between the simulation and the experimental pinhole glitch . We point out that the EXAFS g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 21 Pt 2 شماره
صفحات -
تاریخ انتشار 2014