Comparison between exhaled and sputum oxidative stress biomarkers in chronic airway inflammation.

نویسندگان

  • M Corradi
  • P Pignatti
  • P Manini
  • R Andreoli
  • M Goldoni
  • M Poppa
  • G Moscato
  • B Balbi
  • A Mutti
چکیده

The aim of the present study was to compare aldehyde levels resulting from lipid peroxidation in exhaled breath condensate (EBC) and induced sputum (IS) supernatant of subjects with asthma and chronic obstructive pulmonary disease (COPD). Aldehydes (malondialdehyde (MDA), acrolein, n-hexanal (C6), n-heptanal (C7), n-nonanal (C9), 4-hydroxynonenal (HNE) and 4-hydroxyhexenal (HHE)) in both biological fluids were measured by liquid chromatography-tandem mass spectrometry. MDA concentrations in sputum were 132.5 nM (82.5-268.8) and 23.7 nM (9-53.7) in EBC. Similarly, C6, C7 and C9 concentrations in IS were 1.5-4.7-fold higher than in EBC. Acrolein levels were 131.1 nM (55.6-264.6) in IS and 45.3 nM (14.4-127.1) in EBC. The concentrations of HNE and HHE in IS were not significantly different from the levels in EBC. Aldehyde levels in EBC did not show any correlation with aldehyde levels in IS or with differential sputum cellular count. In COPD, MDA in EBC, but not its IS counterpart, was negatively correlated with the severity of disease. In conclusion, the data presented here show that aldehydes can be detected in both exhaled breath condensate and supernatant of induced sputum, but that their relative concentrations are different and not correlated with each other. Therefore, with regard to lipid peroxidation products, exhaled breath condensate and induced sputum must be considered as independent techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomarkers obtained by non-invasive methods in patients with COPD: where do we stand, what do we expect?

Recently, there has been widespread interest in the use of non-invasive methods for the assessment of airway inflammation in a variety of lung diseases including chronic obstructive pulmonary disease (COPD). Sputum induction is a semi-invasive technique the value of which is not restricted to sputum cell counts, as inflammatory mediators can also be measured in the supernatants. However, none o...

متن کامل

Non-invasive biomarkers and pulmonary function in smokers

Limited information exists regarding measurement, reproducibility and interrelationships of non-invasive biomarkers in smokers. We compared exhaled breath condensate (EBC) leukotriene B4 (LTB4) and 8-isoprostane, exhaled nitric oxide, induced sputum, spirometry, plethysmography, impulse oscillometry and methacholine reactivity in 18 smokers and 10 non-smokers. We assessed the relationships betw...

متن کامل

Exhaled breath condensate biomarkers in COPD.

Biomarkers in chronic obstructive pulmonary disease may be useful in aiding diagnosis, defining specific phenotypes of disease, monitoring exacerbations and evaluating the effects of drugs. Exhaled breath condensate is a noninvasive means of sampling the airways, allowing biomarkers of airway inflammation and oxidative stress to be measured. In the present review, the use of exhaled breath cond...

متن کامل

Usefulness of noninvasive methods for the study of bronchial inflammation in the control of patients with asthma.

Bronchial asthma is one of the most prevalent respiratory conditions. Although it is defined as an inflammatory disease, the current guidelines for both diagnosis and follow-up of patients are based only on clinical and lung function parameters. Current research is focused on finding markers that can accurately predict future risk, and on assessing the ability of these markers to guide medical ...

متن کامل

Correlation of exhaled carbon monoxide and nitric oxide with airflow obstruction in asthma and chronic obstructive pulmonary disease patients

The aim of this study was to quantify lung oxidative stress in patients with asthma and chronic obstructive pulmonary disease by measuring levels of exhaled carbon monoxide and nitric oxide. Levels of exhaled carbon monoxide, nitric oxide were evaluated in exhaled air of asthma and COPD patients. Moreover, correlation of CO and NO concentrations with degree of airflow obstruction (FEV1% predict...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2004