Intervention to reduce inappropriate ionized calcium ordering practices: a quality-improvement project.

نویسندگان

  • Darrell B Newman
  • Konstantinos C Siontis
  • Krishnaswamy Chandrasekaran
  • Allan S Jaffe
  • Deanne T Kashiwagi
چکیده

CONTEXT The importance of an abnormal ionized calcium (iCa) measurement in noncritically ill patients is unclear. Furthermore, iCa monitoring is more expensive than measurement of total calcium and consumes more laboratory resources. We hypothesize that most iCa tests are ordered for routine monitoring in asymptomatic patients, and results do not influence clinical management. OBJECTIVE To characterize and to intervene on iCa test-ordering practices among our institution's hospital-based internal medicine clinicians. DESIGN A quality-improvement project, with retrospective review of clinical records. We retrospectively identified the first 100 consecutive patients admitted to our hospital internal medicine (HIM) services during January 2012 with an iCa test ordered during their hospitalization. We reviewed clinical records to determine the appropriateness of iCa test ordering and of the ordering department. An educational intervention regarding the appropriateness of iCa testing was undertaken targeting HIM clinicians. MAIN OUTCOME MEASURES The effect of the intervention was assessed by identifying a sample of the first 100 consecutive patients admitted to HIM services during November 2012 and by comparing the proportion of iCa tests ordered by HIM clinicians before and after the intervention. RESULTS HIM services were responsible for 38% of iCa measurements before the educational intervention, with the remainder originating primarily from the Emergency Department (29%) and intensive care units (28%). After the intervention, the internal medicine services were responsible for 13% of iCa measurements, which represented a 66% reduction (p = 0.0007). CONCLUSION A simple intervention based on clinician education can reduce the frequency of routine iCa monitoring in stable hospitalized patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging Appropriate Use Criteria For Stress Single-Photon Emission Computed Tomography Sestamibi Studies A Quality Improvement Project

Background—We previously reported the application of the 2005 American College of Cardiology Foundation appropriate use criteria for stress single-photon emission computed tomography (SPECT) imaging to patients at Mayo Clinic (Rochester, MN) in 2005 and 2006. A subsequent internal quality improvement project focused on physician education in an attempt to reduce the rate of inappropriate SPECT ...

متن کامل

Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: a quality improvement project.

BACKGROUND We previously reported the application of the 2005 American College of Cardiology Foundation appropriate use criteria for stress single-photon emission computed tomography (SPECT) imaging to patients at Mayo Clinic (Rochester, MN) in 2005 and 2006. A subsequent internal quality improvement project focused on physician education in an attempt to reduce the rate of inappropriate SPECT ...

متن کامل

A review on laboratory tests’ utilization: A trigger for cutting costs and quality improvement in health care settings

Background: Considering the role of laboratory tests as a central part of controlling health expenditure, this study intends to investigate laboratory tests overutilization in Iran to pave the way for future interventions.   Methods: Inappropriate laboratory utilization was reviewed in a cross-sectional survey through the retrospective analysis of 384 medical records at a tertiary cente...

متن کامل

Integrating Safe Sleep Practices into a Pediatric Hospital: Outcomes of a Quality Improvement Project.

A quality improvement project for implementing safe sleep practices (SSP) was conducted at a large, U.S children's hospital. The intervention involved education of staff and standardization of infant sleep practices utilizing a multifaceted approach. Staff surveys and environmental audits were conducted pre- and post-intervention. Safe Sleep Environment (SSE) audits showed an improvement from 2...

متن کامل

Reducing inappropriate ESR testing with computerized clinical decision support

Laboratory test overutilization increases health care costs, leads to unwarranted investigations, and may have a negative impact on health outcomes. The American Society of Clinical Pathology, in its Choosing Wisely Campaign, advocates that inflammation be investigated with C-reactive protein (CRP) instead of Erythrocyte Sedimentation Rate (ESR). London Health Sciences Centre (LHSC), a tertiary...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Permanente journal

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2015