A cleaning and calibration method for the SpiroPro portable spirometer's pneumotachometer tube in a remote field study.

نویسندگان

  • Matthew R Baldwin
  • William Checkley
  • Robert A Wise
  • Subarna K Khatry
  • Steve C LeClerq
  • Keith P West
چکیده

BACKGROUND We developed a systematic method of cleaning and calibration-checking for the pneumotachometer tube of the SpiroPro portable spirometer; this method maximized spirometry accuracy in a population-based study in a remote area of Nepal. METHODS We tested 10 factory-calibrated pneumotachometer tubes. Each use consisted of a full set of spirometry maneuvers, per the American Thoracic Society (ATS) spirometry criteria. RESULTS The pneumotachometers remained accurate, per the ATS criteria, for 5-9 disinfections, but began to drift toward inaccuracy after the first disinfection. All the pneumotachometers had become inaccurate, per the ATS criteria, after 10 disinfections. CONCLUSIONS In a remote field setting the SpiroPro pneumotachometer tube can be cleaned and reused 5-9 times before it becomes inaccurate per the ATS criteria. Rigorous rinsing in distilled water and repeated calibration checks, at various flows up to 12 L/s, are essential for precise and accurate spirometry with the SpiroPro. Reusing the SpiroPro pneumotachometer in a remote setting may impose measurement bias. Single use of SpiroPro pneumotachometers, albeit more costly, will provide better data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Re. Calibration of peak expiratory flow (PEF) measuring devices.

There are increasing numbers of devices coming onto the market for measuring PEP and of papers assessing their performance. In these papers a number of different ways of calibrating the devices have been used, as discussed in your correspondence columns [1]. What is the best way to calibrate a peak flow (PP) meter for clinical use? It seems not to be realized that compared with a large pneumota...

متن کامل

Design and construction of a portable unite for measuring body-fluid components

Introduction: In the laboratory, the time required to measure body-fluids components is usually one to two working days. The laboratory methods require sample preparation and instrument cleaning after the sample reading. In emergency scenarios, the physician does not have much time to make a clinical decision. To solve these challenges, a portable system for measuring the body fluids components...

متن کامل

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

Impact of positive pressure ventilation on thoracostomy tube removal in traumatic patients who admitted in ICU

Introduction: Few studies is in literature related to evaluation of impact of positive pressure ventilation (PPV) on thoracostomy tube removal in Iran. We decided, in this study, to evaluate the impact of PPV on recurrent pneumothorax (PTX) after removal of thoracostomy tubes (TT). Methods: A case-control study was performed for evaluating 122 chest tubes in 109 mechanically ventilatedtrauma pa...

متن کامل

Magnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems

In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2010