Carcinoma of the Pancreas and Selectron Brachytherapy

نویسندگان

  • Michael Golby
  • C. Giles Rowland
چکیده

Carcinoma of the pancreas is now the fourth most common malignancy in many parts of the world. It is the major neoplasm in the hepato-biliary system which presents frequently as inoperable. It responds poorly to tele-radiotherapy and even bypass surgery gives the patient a very short time of relief. A search of the literature reveals the present dismal progress, even though the resection rate is rising and the operative mortality falling, results are still poor. Trede (1985) quotes resection as 21.3% of whom 28% survive 5 years for adeno carcinoma of the head of the pancreas. The resection rate of periampullary carcinoma is steady at 73% with a 50%

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characteristics of 137Cs sources used in after loading Selectron system by Monte Carlo method

Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...

متن کامل

Simulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources

Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet s...

متن کامل

Carcinoma Cervix-A Prospective Randomised Study

The aim of this study was to determine whether the addition of concurrent cisplalin and hyperfractionation in external pelvic radiotherapy improves local control and survival in paticnts with locally advanced carcinoma cervix as compared to treatment with conventional radiolherap.J alonc. The morbidity oftwo treatment protocols was also compared. Sixty patients of ne" I) diagnosed squamous cell...

متن کامل

Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

متن کامل

A novel phantom design for brachytherapy quality assurance

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...