BACKGROUND We evaluated a new, automated multicapillary zone electrophoresis (CE) instrument (Capillarys), 4.51 software version; Sebia) for human serum protein analysis. METHODS With the Capillarys beta1-beta2+ reagent set, proteins were separated at 7 kV for 4 min in 15.5 cm x 25 micro m fused-silica capillaries (n = 8) at 35.5 degrees C in a pH 10 buffer with online detection at 200 nm. Serum samples with different electrophoretic patterns (n = 265) or potential interference (n = 69) were analyzed and compared with agarose gel electrophoresis (AGE; Hydrasys)-Hyrys, Hydragel protein(e) 15/30 reagent set; Sebia). RESULTS CVs were <3.5% for albumin, <11% for alpha(1)-globulin, <4.1% for alpha(2)-globulin, <7.4% for beta-globulin, and <5.8% for gamma-globulin (3 control levels); measured throughput was 60 samples/h. In patients without paraprotein (n = 116), the median differences between CE and AGE were -5.4 g/L for albumin, 4.0 g/L for alpha(1)-globulin, 0.7 g/L for alpha(2)-globulin, 0.6 g/L for beta-globulin (P <0.001 for all fractions), and -0.1 g/L for gamma-globulin (not significant). More samples had at least one gamma-migrating peak detected by CE (n = 135 vs 130; paraprotein detection limit, approximately 0.5-0.7 g/L), but fewer were quantified (n = 84 vs 91) because of gamma- to beta-migration shifts. There was a 1.2 g/L median difference between CE and AGE for gamma-migrating paraprotein quantification (n = 69; P <0.001). Several ultraviolet-absorbing substances (lipid emulsion, hemoglobin) or molecules (contrast agent, gelatin-based plasma substitute) induced CE artifacts. CONCLUSIONS The Capillarys instrument is a reliable CE system for serum protein analysis, combining advantages of full automation (ease of use, bar-code identification, computer-assisted correction of alpha(1)-globulins) with high analytical performances and throughput.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sample preparation for the analysis of complex carbohydrates by multicapillary gel electrophoresis with light-emitting diode induced fluorescence detection.

This paper evaluates various sample preparation methods for multicapillary gel electrophoresis based glycan analysis to support electrokinetic injection. First the removal of excess derivatization reagent is discussed. Although the Sephadex G10 filled multiscreen 96-well filter plate and Sephadex G10 filled pipet tips enabled increased analysis sensitivity, polyamide DPA-6S pipet tips worked pa...

متن کامل

Boronic acid lectin affinity chromatography (BLAC). 2. Affinity micropartitioning-mediated comparative glycosylation profiling.

As a continuation of our work on boronic acid lectin affinity chromatography (BLAC), in this paper we introduce an automated affinity micropartitioning approach using combined boronic acid and concanavalin A (BLAC/Con A) resin-filled micropipette tips to isolate and enrich human serum glycoproteins. The N-linked oligosaccharides of the partitioned glycoproteins were removed by PNGase F enzyme d...

متن کامل

Evaluation of Acetonitrile Deproteinisation of the Serum Samples for the Analysis of Drugs in Serum Using Capillary Zone Electrophoresis

Deproteinisation with acetonitrile (along with methanol or other reagents) is a useful and rapid technique in analysis of drugs or their metabolites in human serum. In this paper application of this simple technique in biopharmaceutical analysis using capillary electrophoresis (CE) is evaluated. Some drugs with different ionic and protein binding properties were selected and dissolved in human ...

متن کامل

Evaluation of Acetonitrile Deproteinisation of the Serum Samples for the Analysis of Drugs in Serum Using Capillary Zone Electrophoresis

Deproteinisation with acetonitrile (along with methanol or other reagents) is a useful and rapid technique in analysis of drugs or their metabolites in human serum. In this paper application of this simple technique in biopharmaceutical analysis using capillary electrophoresis (CE) is evaluated. Some drugs with different ionic and protein binding properties were selected and dissolved in human ...

متن کامل

Evaluation of Acetonitrile Deproteinisation of the Serum Samples for the Analysis of Drugs in Serum Using Capillary Zone Electrophoresis

Deproteinisation with acetonitrile (along with methanol or other reagents) is a useful and rapid technique in analysis of drugs or their metabolites in human serum. In this paper application of this simple technique in biopharmaceutical analysis using capillary electrophoresis (CE) is evaluated. Some drugs with different ionic and protein binding properties were selected and dissolved in human ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 49 11  شماره 

صفحات  -

تاریخ انتشار 2003