Laryngeal Ultrasonography Versus Cuff Leak Test in Predicting Postextubation Stridor

نویسندگان

  • Haleh Mikaeili
  • Mohammad Yazdchi
  • Mohammad Kazem Tarzamni
  • Khalil Ansarin
  • Maryam Ghasemzadeh
چکیده

INTRODUCTION Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngeal ultrasonography versus cuff leak test in predicting postextubation stridor. METHODS In a prospective study, all patients intubated for a minimum of 24 h for acute respiratory failure, airway protection and other causes were included. Patients were evaluated for postextubation stridor and need for reintubation after extubation. The cuff leak volume was defined as a difference between expiratory tidal volumes with the cuff inflated and deflated. Laryngeal air column width was defined as the width of air passed through the vocal cords as determined by laryngeal ultrasonography. The air-column width difference was the width difference between balloon-cuff inflation and deflation. RESULTS Forty one intubated patients with the mean age of 57.16±20.07 years were included. Postextubation stridor was observed in 4 patients (9.75%). Cuff leak test (cut off point: 249 mL) showed sensitivity and specificity of 75% and 59%, respectively. In addition, laryngeal ultrasonography (cut off point for air column width: 10.95 mm) resulted in sensitivity and specificity of 50% and 54%, respectively. Positive predictive value of both methods were <20%. CONCLUSION Both cuff leak test and laryngeal ultrasonography have low positive predictive value and sensitivity in predicting postextubation stridor and should be used with caution in this regard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of the cuff leak test in predicting the effects of corticosteroid treatment on postextubation stridor.

BACKGROUND There is not enough evidence to determine the most appropriate treatment of postextubation stridor. Although the cuff leak test is a simple method to predict postextubation stridor, little is known about its use in monitoring the effects of steroid treatment for this complication. The aim of this study was to evaluate the effect of steroids on postextubation stridor based on the clin...

متن کامل

Postextubation laryngeal edema and stridor resulting in respiratory failure in critically ill adult patients: updated review

Endotracheal intubation is frequently complicated by laryngeal edema, which may present as postextubation stridor or respiratory difficulty or both. Ultimately, postextubation laryngeal edema may result in respiratory failure with subsequent reintubation. Risk factors for postextubation laryngeal edema include female gender, large tube size, and prolonged intubation. Although patients at low ri...

متن کامل

The endotracheal tube cuff-leak test as a predictor for postextubation stridor.

BACKGROUND The endotracheal tube (ETT) cuff-leak test (CLT) has been proposed as a relatively simple, noninvasive method for detecting the presence of laryngeal edema prior to tracheal extubation. OBJECTIVE To determine the value of the CLT for predicting postextubation stridor (PES) among medical and surgical patients, and to assess the impact of certain variables on the incidence of PES. ...

متن کامل

Cuff-leak test for predicting postextubation airway complications: a systematic review.

BACKGROUND AND OBJECTIVE Postextubation problems such as laryngeal edema and reintubation are common complications after tracheal intubation. The cuff-leak test has been proposed as a method of identifying those patients at high risk in clinical practice, but its efficacy remains controversial. METHODS We searched electronic databases including PubMed, the Cochrane Controlled Trials Register,...

متن کامل

Laryngeal ultrasound: a useful method in predicting post-extubation stridor. A pilot study.

The cuff-leak test was widely used for the prediction of post-extubation stridor, but controversial results limit its clinical application. The current study used real-time ultrasonography to evaluate the air-leak and hypothesised that the air-column width, measured by ultrasonography, may be correlated to the development of post-extubation stridor. From June 1, 2001 to March 1, 2002, a total o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014