Optimization modeling of analyte adhesion over an inclined microcantilever-based biosensor
نویسنده
چکیده
The effect of the microcantilever inclination on analyte adhesion is numerically analyzed in this work. A generalized model for the analyte adhesion is considered based on wall shear stress (WSS) at the microcantilever surface. Several analytical solutions for special cases are obtained. It is found numerically that the total mass transfer is enhanced by increasing the adhesion rate, the Peclet number and the use of converging flows over the microcantilever. Further, it is found that there exists a critical Peclet number that can maximize the total mass transfer when WSS slows down the adhesion process. The critical Peclet number increases as adhesion rate increases while it decreases as the flow becomes more convergent. Correlations are established on the basis of the numerical simulations for predicting flow operating conditions inside fluidic cells under maximized mass transfer rate conditions. Finally, this work paves the way for future experimental work in this area.
منابع مشابه
Micro-cantilevered MEMS Biosensor for Detection of Malaria Protozoan Parasites
In this paper, the presented work aims to provide a designed model based on Finite element method for detection of Malaria protozoan parasites. Micro-cantilevers are next generation highly efficient biosensors for detection and prevention of any disease. Here, an E-shaped model for micro cantilevered biosensor is designed using COMSOL Multiphysics specifically for detection of Malaria. Microcan...
متن کاملCalculation of Stress And Deflection In Double Layer Microcantilever For Biosensor Application
In microcantilever-based biosensor, a sensitive layer plays an important role as a place for the establishment of functional layer for detecting molecules target. When a sensitive layer is coated on the microcantilever surface, a surface stress change is induced as a consequence of adsorbate-surface interaction, resulting in a deflection of the microcantilever. However, the microcantilever with...
متن کاملPilot Application of Magnetic Nanoparticle-Based Biosensor for Necrotizing Enterocolitis.
BACKGROUND Necrotizing Enterocolitis (NEC) is a major source of neonatal morbidity and mortality. There is an ongoing need for a sensitive diagnostic instrument to discriminate NEC from neonatal sepsis. We hypothesized that magnetic nanopartile-based biosensor analysis of gut injury-associated biomarkers would provide such an instrument. STUDY DESIGN We designed a magnetic multiplexed biosens...
متن کاملTwo-curve-shaped biosensor using photonic crystal nano-ring resonators
We design a novel nano-ring resonator using two-dimensional photonic crystal (2D-PhC), for bio-sensing applications. The structure of biosensor is created by two-curve-shaped ring resonator which sandwiched by two waveguides. These are configured by removing one row of air holes. The refractive index of sensing hole is changed by binding an analyte. Hence, intensity of the transmission spectrum...
متن کاملSpatial optimization of an array of aligned microcantilever based sensors
The present work establishes the optimized spatial arrangement for an array of aligned microcantilever sensors placed inside a fluidic cell. The results of the present investigation show that the optimum spacing distance between the microcantilevers decreases as the fluidic cell height decreases. An increase in the flow Reynolds number is found to increase the optimum spacing distance. However,...
متن کامل