Analysis of complications after surgical repair of orbital fractures.

نویسندگان

  • Matteo Brucoli
  • Francesco Arcuri
  • Roberta Cavenaghi
  • Arnaldo Benech
چکیده

BACKGROUND The term "orbital blow-out fracture" is referred to as the mechanism by which an impact to the eyeball is transposed as a mechanical energy to the orbital walls, causing them to fracture. Despite a proper surgical technique, a successful anatomic reconstruction of the orbit, and an accurate follow-up, 3 complications are still frequently observed at long-term follow-up: diplopia, enophthalmos, and hypesthesia of the infraorbital nerve territory. In this retrospective study, we analyze the incidence, the specific characterization, and the potential risk factors of these 3 complications. METHODS The records of 75 patients who underwent surgical repair of isolated orbital blow-out fracture from January 2001 to December 2007 at the Maxillofacial Surgery Unit of the Novara Major Hospital were reviewed retrospectively. Patients who had other coexisting facial fractures or orbital rim involvement were excluded from this study. The mean follow-up reached 39 months (range, 6-81 months). Enophthalmos was measured by a Hertel exophthalmometer; diplopia was evaluated by an optometrist with cover test, red glass test, and Hess-Lancaster test; and hypesthesia of the infraorbital nerve territory was checked by clinical examination. The studied parameters included patient's age and sex, time interval between trauma and surgery, location of the fracture, and implant material. The χ test for nonparametric data was used, and a P value of less than 0.05 was considered statistically significant. RESULTS Sex, location of the fracture, and implant material were not considered statistically significant (P > 0.05). The unique variable that influenced our data was the time interval between trauma and surgery (P > 0.05). DISCUSSION Although the surgical technique was executed properly and the immediate postoperative recovery was uneventful, diplopia, enophthalmos, and infraorbital nerve dysfunction were the frequent complications. We stress the fact that orbital blow-out fracture is generally not considered a technically demanding procedure, but the outcome can be very disappointing; the surgical procedure must be managed very carefully by experienced surgeons to lower the high rates of these 3 common complications. However, we can report that the incidence of diplopia, enophthalmos, and infraorbital nerve dysfunction are decreased by an immediate intervention and an early surgical repair of the orbital blow-out fracture. Patients who had surgery within 2 weeks of trauma have a lower risk to develop postoperative complications; this study supports an early surgical treatment of orbital blow-out fractures, when it is indicated.

منابع مشابه

Endoscopic endonasal repair of orbital floor fracture.

BACKGROUND High-resolution endoscopes and the advent of endoscopic instruments for sinus surgery provide surgeons with excellent endonasal visualization and access to the orbital walls. OBJECTIVE To demonstrate repair of orbital floor blowout fractures through an intranasal endoscopic approach that allows repair of the orbital floor fracture and elevation of the orbital content using a balloo...

متن کامل

Early versus late repair of orbital blowout fractures.

BACKGROUND AND OBJECTIVE To compare early and late surgical repair of orbital blowout floor fractures. PATIENTS AND METHODS A retrospective, comparative interventional case series reviewed medical records of 50 consecutive patients who underwent unilateral orbital floor fracture repair in a 4-year period. Comparative analysis was performed between patients operated on within 2 weeks of injury...

متن کامل

Surgical Outcome of Blowout Fractures of Floor of Orbit: A Case Series of 5 Patients

Purpose: To report the surgical outcome of traumatic blow out fractures of the floor of the orbit. Materials and methods: Five patients who sustained orbital floor blowout fracture following trauma underwent surgical repair via trans-conjunctival or subciliary approaches. One patient had sustained bilateral blowout fracture. Three patients presented with symptoms early following the fracture wi...

متن کامل

Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

BACKGROUND Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. METHODS This prospective study was conducted on the medical records and radiology records...

متن کامل

Use of copolymer polylactic and polyglycolic acid resorbable plates in repair of orbital floor fractures.

The fractures of the orbital floor are common after craniofacial trauma. Repair with resorbable plates is a viable reconstructive option; however, there are few reports in the literature. This study describes our experience using copolymer polylactic and polyglycolic acid (PLLA/PGA) orbital reconstruction plates (LactoSorb, Lorenz Surgical, Jacksonville, FL) in 29 cases of the orbital floor fra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • The Journal of craniofacial surgery

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 2011