Inaccuracy detected in acid phosphatase kit method.

نویسنده

  • D Bogdan
چکیده

Output peak distortion and noise are a problem in the AutoAnalyzer II (Technicon Instruments Corp., Tarrytown, N. Y. 10591) direct cholesterol procedure no. SE4-0026 FC4. We originally believed this difficulty to be inherent in the two-step sampling procedure used in this method, but we later observed sample diluent back-up into the bubbler tube of the original injector block, apparently because of the relatively large cross-sectional area and the resulting dead-space volume of the bubbler tube. This effect may have been increased by the relatively large sample volume (0.4 ml) introduced. The fluid level in the bubbler tube varied continually. Hence sample slug length and concentration varied, producing considerable noise and abnormally shaped output curves. The following modifications considerably reduce noise and improve the output curve shape in this procedure. (a) Replace the sample injector fitting no. 116-0490-01 with injector fitting no. 177-B004-02, which has a considerably smaller cross-sectional area and interacts little with stream flow, except during bubbling. (b) Replace the original sample diluent (distilled water) with a 2 g/liter solution of the surfactant Brij-35, which improved bubble pattern. (c) Replace the pump tube feeding the sample injector bubbler so as to decrease the flow rate from 0.42 ml/min (no. 116-0549-08 tubing) to 0.32 ml/min (no. 116-0549-07 tubing), to limit surging. (d) Rotate the AlO (no. 116-B034-01) sample fitting from parallel to upright position. These modifications have significantly decreased both the coefficients of variation as well as the frequency of need to repeat assays. Three controls, a borderline low, borderline high, and normal were used for two months before the modification and two months afterwards. The coefficients of variation before the modification were 2.8, 3.7, and 3.1%, respectively, as compared with 1.6, 2.5, and 1.1% afterward. The probability (P) that these improvements in precision occurred by chance are less than 0.01, 0.05, and 0.001, respectively (F test). Student’s t-test showed no significant difference in the means at any of the three analyte concentrations before and after modification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

P-10: Effects of Cadmium on Reproductive Enzymes of Blood and Reproductive Tissues in Adult Male Mice

Background: Heavy metals such as cadmium (Cd2+) are natural components of the Earth's crust which can not be degraded or destroyed. Industrial, mining and agricultural activities, particularly the excessive use of phosphate fertilizers, have led to high levels of cadmium contamination at many locations worldwide. Some toxic effects of cadmium are due to its inhibition of various enzyme sys...

متن کامل

European specifications for imprecision and inaccuracy compared with operating specifications that assure the quality required by US CLIA proficiency-testing criteria.

Proposed and interim European quality specifications for imprecision and inaccuracy have been compared with the US CLIA total error criteria for proficiency testing (PT). To assess the relative demands of separate imprecision and inaccuracy specifications vs total error criteria, we derived the imprecision and inaccuracy that would be allowable if a testing process were to provide 90% assurance...

متن کامل

Interferences in the direct kinetic determination of acid phosphatase activity.

594 CLINICALCHEMISTRY,Vol. 30, No. 4, 1984 that the preservatives used had no effect on the MCP-NAG assay but that NAG activity declined when the urine pH was >8.0 and this decline became more marked on storage. This test kit provides a rapid method of estimating urinary NAG and can be used with a simple spectrophotometer. The lack of any reference standard is a drawback, but we understand it i...

متن کامل

Serum acid phosphatase activity in diabetes mellitus.

Lysosomal enzymes acid phosphatase show increase in diabetes mellitus and this is closely related to diabetic metabolic alterations. This was a crosssectional study conducted on 50 diabetic subjects (25 patients with complications and 25 patients without complications) in RIMS hospital during the period from September 2010 to August 2012. Twenty five age and sex matched healthy individual were ...

متن کامل

Canine serum alkaline phosphatase isoenzymes detected by polyacrylamide gel disk electrophoresis.

Serum alkaline phosphatase (ALP) isoenzymes were studied in normal dogs using a commercially available polyacrylamide gel disk electrophoresis kit (PAG/disk kit). Serum samples taken from the dogs were incubated with neuraminidase, after which most showed ALP isoenzymes as two characteristic stained bands. To determine the origin of each band, ALP isoenzymes of serum and tissue extracts (liver,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 1978