Geometric and Radiometric Evaluation of the Potential of a High Resolution Cmos -camera
نویسندگان
چکیده
The progress of digital imaging systems has created manifold opportunities and new applications to close range photogrammetry. The classical techniques have found significant changes and this seems to be an ongoing process which is heavily influenced by new technologies showing up on the sensor market. CMOS (Complimentary Metal Oxide Semiconductor) sensors are on of the challenges to CCD sensors as they are providing a similar performance at a cheaper price level. One of the demands is to investigate the radiometric and geometric characteristics of the imaging sensor. This includes considering other factors involved in image acquisition with CMOS sensors and requires a detailed analysis on the factors and its effects for the overall performance of CMOS cameras. This paper analyses the radiometric and geometric performance of the Canon EOS-1Ds, a high resolution CMOS camera. Presented are issues of restoration and geometric correction as well as an experimental investigation using different Canon EOS-1Ds images. Visual inspection and quantitative analysis of the obtained results demonstrate the high productive capability of the Canon EOS-1Ds camera. *Corresponding author.
منابع مشابه
Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملDiagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries
Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...
متن کاملA 12 bit 76MS/s SAR ADC with a Capacitor Merged Technique in 0.18µm CMOS Technology
A new high-resolution and high-speed fully differential Successive Approximation Register (SAR) Analog to Digital Converter (ADC) based on Capacitor Merged Technique is presented in this paper. The main purposes of the proposed idea are to achieve high-resolution and high-speed SAR ADC simultaneously as well. It is noteworthy that, exerting the suggested method the total capacitance and the rat...
متن کاملGeometric and Radiometric Modeling of the Martian Surface Based on Object Space Matching and Photoclinometry
The unique image data of the High Resolution Stereo Camera (HRSC) on Mars Express enable for systematic derivation of Digital Terrain Models (DTMs) and orthoimages. Consequently, several photogrammetric processing algorithms have been investigated with HRSC imagery. The results form the basis for further research including photometric analysis. Within this paper, an integrated approach for phot...
متن کاملEvaluation of Similarity Measures for Template Matching
Image matching is a critical process in various photogrammetry, computer vision and remote sensing applications such as image registration, 3D model reconstruction, change detection, image fusion, pattern recognition, autonomous navigation, and digital elevation model (DEM) generation and orientation. The primary goal of the image matching process is to establish the correspondence between two ...
متن کامل