Auditory backup alarms: distance-at-first-detection via in-situ experimentation on alarm design and hearing protection effects.
نویسندگان
چکیده
UNLABELLED The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. METHOD Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. RESULTS A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. DISCUSSION For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them more time to react to approaching vehicles. The results of this study suggest that as the attenuation of the hearing protectors increases, precautions should be considered by safety professionals. This is because, as it was the case with the Bilsom passive earmuff and E-A-R/3M Combat ArmsTM earplug-passive steady state, high attenuation minimizes the detection distance and as a result on-foot workers will have less time to react to any approaching vehicle. The main effects of the type of backup alarm signal demonstrated a statistically-significant advantage of the standard backup alarm over the broadband backup alarm on detection distance in feet. The magnitude of the improvement produced by the standard backup alarm was 221.5 feet, a very large margin. For example, with a vehicle backing at 10 mph, the 221.5 ft decrease in detection distance with the Brigade alarm equates to the vehicle arriving 15 seconds sooner at the worker from the point at which its alarm was first heard.
منابع مشابه
Failure to Detect Critical Auditory Alerts in the Cockpit: Evidence for Inattentional Deafness
OBJECTIVE The aim of this study was to test whether inattentional deafness to critical alarms would be observed in a simulated cockpit. BACKGROUND The inability of pilots to detect unexpected changes in their auditory environment (e.g., alarms) is a major safety problem in aeronautics. In aviation, the lack of response to alarms is usually not attributed to attentional limitations, but rather...
متن کاملPerceived urgency and the anaesthetist: responses to common operating room monitor alarms.
Increasing numbers and varieties of electronic monitors are used in hospital operating rooms. Many of these are equipped with auditory alarms which are loud, insistent, or irritating, and thus are frequently disabled by the anaesthetist. This study was planned to evaluate two components of auditory alarm design which may influence the usefulness of the alarm: the perceived urgency of the audito...
متن کاملTOPIC CHOICE: SURFACE TRANSPORTATION SYSTEMS (driver behavior) Effects of Single versus Multiple Warnings on Driver Performance (9 words OK) RUNNING HEAD: Effects of Single versus Multiple Alarms (35 chars w/spaces OK)
212 words OK) Objective: To explore how a single master alarm system affects drivers’ responses when compared to multiple, distinct warnings. Background: Advanced driver warning systems are intended to improve safety, yet inappropriate integration may increase the complexity of driving, especially in high workload situations. This study investigated the effects of auditory alarm scheme, reliabi...
متن کاملHuman Factors in Organizational Design and Management – Xi Nordic Ergonomics
Constantly increasing and more complex information flows in industrial control rooms raise the risk that operators will become distracted, confused, and visually overloaded during demanding situations. New multimodal interfaces could offer better solutions. In this work, we focus on alarm sound design. Alarms serve to alert operators to deviations from normal conditions and enable operators to ...
متن کاملAuditory Memory deficit in Elderly People with Hearing Loss
Introduction: Hearing loss is one of the most common problems in elderly people. Functional side effects of hearing loss are various. Due to the fact that hearing loss is the common impairment in elderly people; the importance of its possible effects on auditory memory is undeniable. This study aims to focus on the hearing loss effects on auditory memory. Materials and Methods: Dichotic Audi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Work
دوره 41 Suppl 1 شماره
صفحات -
تاریخ انتشار 2012