Quality control, accuracy, and prediction capacity of dual energy X-ray absorptiometry variables and data acquisition.
نویسندگان
چکیده
The acquisition of soft tissue measurements, fat (chemical) or adipose tissue (morphological) quantities, is essential in clinical research and nutritional status and its associated health risks. This has led to a proliferation of methods for the in-vivo determination of body composition. None of the indirect in-vivo approaches to estimate body adipose tissue has been validated against direct dissection data except for the skinfold.Since the development of DEXA as a measurement tool of bone density and mineral content for the detection of osteoporosis, it became a tool for measuring regional and whole body masses, lean tissue, and fat. A number of validation attempts have been made, however mostly against other indirect in-vivo techniques. The purpose of this study was to conduct an in-vitro validation and quality control of the data acquisition of DEXA using dissection as the criterion method. Fourteen porcine hind legs were scanned with DEXA, weighed in air and water and dissected into skin, adipose tissue, muscle and bone. Normal distribution, means, standard deviations, paired student t-test, Pearson correlation coefficients, interclass correlations test, and a Bland-Altman plot were used. The results show systematically good to excellent correlations between DEXA and dissection data acquisition (r(2)=0.75 to 0.99), but absolute indirect DEXA and direct dissection values are significantly different (p<0.05). DEXA overestimates total weight, lean mass, and fat free mass and underestimates both mass and % adipose tissue. DEXA provides erroneous values for bone density. Data produced by DEXA are morphological, not chemical values, as claimed by the manufacturer. This 'pilot' study indicates that a 'simple' combination of skin, adipose tissue, muscle, and bone from hind legs may give an incomplete picture of reality as one needs to measure viscera, connective tissue, and air pockets of the body. Validation studies with intact bodies are advised.
منابع مشابه
Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...
متن کاملComparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملAssessment of bone mineral density with dual energy X-ray absorptiometry in pre- and post-menopausal women
Background: Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry (DXA) equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine LS in pre- and post-menopausal women f...
متن کاملMonte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique
Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures. A timely and accurate diagnosis of this disea...
متن کاملQuality Control , AccuracM and Prediction Capacity of Dual Energy X - ray Absorptiometry Variables and Data Acquisition
The acquisition of soft tissue measurements, fat (chemical) or adipose tissue (morphological) quantitics, is essential in clinical research and nutritional status and its associated health risks, This has led to a proliferation of methods for the in-vivo deterrnination of body composition, None of the indirect in-vivo approaches to estimate body adipose tissue has been validated against direct ...
متن کاملDual-energy X-ray absorptiometry diagnostic discordance between Z-scores and T-scores in a young Iranian population
Background: Dual-energy X-ray Absorptiometry (DXA) is considered the gold standard for non-invasive measurement of bone mass. T-scores and Z-scores are used to present the results of bone mass. The present study was designed to evaluate the discordance between T-scores and Z-scores calculated at a same level and its relation with age, gender and body mass index (BMI) in a representative sampl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of physiological anthropology
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2008