Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience

نویسندگان

  • Vassiliki Vlachopoulou
  • Christos Antypas
  • Harry Delis
  • Argyrios Tzouras
  • Nikolaos Salvaras
  • Dimitrios Kardamakis
  • George Panayiotakis
چکیده

BACKGROUND Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influence of the supplemental shielding, the number of monitor units and the collimator size to the peripheral dose were investigated. METHODS MOSFET dosimeters were placed in preselected anatomical regions of the patient undergoing Cyberknife treatment, namely the thyroid gland, the nipple, the umbilicus and the pubic symphysis. RESULTS The mean peripheral doses before the supplemental shielding was added to the Cyberknife unit were 51.79 cGy, 13.31 cGy and 10.07 cGy while after the shielding upgrade they were 38.40 cGy, 10.94 cGy, and 8.69 cGy, in the thyroid gland, the umbilicus and the pubic symphysis, respectively. The increase of the collimator size corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and collimator scatter. CONCLUSION Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

CyberKnife radiosurgery for spinal neoplasms.

The role of stereotactic radiosurgery for the treatment of intracranial lesions is well established. Its use for the treatment of spinal lesions has been limited by the availability of effective target immobilization and localization technologies. Conventional external beam radiotherapy lacks the precision to allow delivery of large doses of radiation near radiosensitive structures such as the ...

متن کامل

Cyberknife radiosurgery for benign meningiomas: short-term results in 199 patients.

OBJECTIVE To present initial, short-term results obtained with an image-guided radiosurgery apparatus (CyberKnife; Accuray, Inc., Sunnyvale, CA) in a series of 199 benign intracranial meningiomas. METHODS Selection criteria included lesions unsuitable for surgery and/or remnants after partial surgical removal. All patients were either symptomatic and/or harboring growing tumors. Ninety-nine t...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Integration of Functional MRI and White Matter Tractography in CyberKnife Radiosurgery

PURPOSE To investigate the efficacy of the integration of functional magnetic resonance imaging and diffusion-tensor imaging tractography data into CyberKnife radiosurgery for intracranial tumor management. MATERIALS AND METHODS Functional neuroimaging, anatomical magnetic resonance imaging, and computed tomography images of patients with brain lesions in critical areas were acquired before r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011