Preliminary Shielding Analysis and Design of the Remote Maintenance Cells for the Proposed National Spallation Neutron Source (nsns)
نویسندگان
چکیده
Radiation shielding analysis and design calculations were performed for remote maintenance cells of the proposed National Spallation Neutron Source (NSNS) facility. In the analysis, a calculational strategy utilizing coupled high energy Monte Carlo calculations and multidimensional discrete ordinates calculations was implemented to perform an activation analysis and shielding assessment of the NSNS remote handling cells. A general description of the remote maintenance cells, the methodology employed, and preliminary results of the shielding analysis and recommendations are presented.
منابع مشابه
Shielding studies on a total-body neutron activation facility
Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
متن کاملThe comparison between simple and advanced shielding materials for the shield of portable neutron sources
Background: Monte Carlo simulations play a vital role in the calculation of the necessary shielding both for neutrons and photons. Advanced and simple shielding materials against neutron and gamma rays were compared by simulation using the MCNB4B Monte Carlo code. The simulations were carried out for the three common neutron sources, namely the 252Cf, the 241Am/Be and the DD neutron generator w...
متن کاملTitle Design of light element analysis system in BNCT and every NCT
Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...
متن کاملUtilization of Monte Carlo Calctilations in Radiation Transport Analyses to Support the Design of the U. S. Spallation Neutron Source (SNS)
The Department of Energy (DOE) has given the Spallation Neutron Source (SNS) project approval to begin Title I design of the proposed facility to be built at Oak Ridge National Laboratory (ORNL) and construction is scheduled to commence in EyOl . The SNS initially will consist of an accelerator system capable of delivering an -0.5 microsecond pulse of 1 GeV protons, at a 60 Hz frequency, with 1...
متن کاملA review on neutron shielding performance of nano-composite materials
Neutron sources employed in different applications in both medicine and industry. Due to the harmful effects of neutron particles on living organisms, radiation shields have played a vital role in radiation protection against neutrons. In recent decade, numerous investigations conducted on the design and fabrication of nanocomposites as more efficient shielding materials against fast and therma...
متن کامل