Laparoscopic Guidance or Revision of Ventriculoperitoneal Shunts in Children
نویسندگان
چکیده
BACKGROUND Ventriculoperitoneal shunt is the preferred treatment for hydrocephalus. Known complications include infection, obstruction, and disconnection with the fractured fragment migrating in the peritoneal cavity. We report 17 cases of laparoscopic evaluation and revision of ventriculoperitoneal shunts in children. METHODS From January 2000 through October 2002, we retrospectively reviewed our experience with laparoscopy and ventriculoperitoneal shunts. RESULTS Laparoscopy was performed in 17 children with a malfunctioning shunt, presumed shunt dislodgment or disconnection, reinsertion of a shunt after externalization, and primary shunt placement. Six patients (35%) were converted to an open laparotomy due to dense adhesions. Eleven patients (65%) underwent successful laparoscopic-assisted ventriculoperitoneal shunt placement: 5/11 (45%) had lysis of adhesions or pseudocyst marsupialization with repositioning of a functional shunt, or both; 3/11 (27%) had successful retrieval of a disconnected catheter with reinsertion of a new catheter; 2/11 (18%) had laparoscopic confirmation of satisfactory placement and function, requiring no revision; 1/11 (9%) had an initial shunt placed with laparoscopic guidance due to the obesity. Operative time for the laparoscopic procedure ranged from 30 minutes to 60 minutes. All laparoscopic procedures used 1-mm or two 5-mm ports. Perioperatively, no adverse neurological sequelae occurred due to the pneumoperitoneum. CONCLUSIONS Laparoscopic guidance or revision of ventriculoperitoneal shunts permits (1) direct visualization of catheter insertion within the peritoneal cavity, (2) satisfactory positioning, (3) lysis of adhesions or marsupialization with catheter repositioning, or both, and (4) retrieval of fractured catheters.
منابع مشابه
Laparoscopic versus non-laparoscopic-assisted ventriculoperitoneal shunt placement in adults. A retrospective analysis.
BACKGROUND Ventriculoperitoneal shunts and distal shunt revisions bear a high risk of distal malfunction, especially in patients with previous abdominal pathologies as well as in obese patients. We performed laparoscopy-guided distal shunt placement or revision for patients with and without a positive abdominal history. We review the indications, techniques, complications, and long-term outcome...
متن کاملLaparoscopic Hysteropexy in a Patient with Spina Bifida and Ventriculoperitoneal Shunt
Laparoscopic repair of pelvic organ prolapse in patients with ventriculoperitoneal shunts has not been previously described. The optimum management of patients with ventriculoperitoneal shunts undergoing laparoscopy is uncertain. We describe the case of a 21-year-old female patient with spina bifida and ventriculoperitoneal shunt who underwent laparoscopic hysteropexy for severe pelvic organ pr...
متن کاملEvaluation of ventriculoperitoneal shunt malfunction regarding ventricular catheter placement
AbstractBackgroundline of treatment for management of hydrocephalus despite available new techniques andsystems of shunting. Associated complications should be recognized and managed properly,but the most recognized complications are shunt obstruction which its prevalencethrough surgical approach is discussed here. Two approaches (frontal and parietal) are usedto insert ventriculoperitoneal shu...
متن کاملSuccess rates and complications of ventriculoperitoneal and ventriculoatrial shunting: A systematic review
Background and Aims: The insertion of ventriculoperitoneal (VP) and ventriculoatrial (VA) shunts is the first-line treatment of patients with hydrocephalus and normal-pressure hydrocephalus. The provision of a safety profile for shunting in the treatment of hydrocephalus patients is very important. This study aimed to determine the success rates and complications of VP and VA shunting in patien...
متن کاملExtracranial complications of cerebrospinal fluid shunt function in childhood hydrocephalus.
There were 112 separate hospital evaluations in 84 patients for suspected shunt malfunction: 96 evaluations were of ventriculoperitoneal shunts, 13 were of ventriculoatrial shunts, and three were of both types of shunts. In 45 (47%) of 96 ventriculoperitoneal shunts, complications eventually led to surgical revision; 20 (44%) of these were problems of the peritoneal end and therefore peculiar t...
متن کامل