Evaluation of BACTEC MYCO/F lytic medium for recovery of mycobacteria and fungi from blood.

نویسندگان

  • R T Waite
  • G L Woods
چکیده

The reliability of MYCO/F Lytic medium in the BACTEC 9240 blood culture system was evaluated by comparing its performance to that of the Isolator system for the recovery of fungi and to that of the ESP II system for the recovery of mycobacteria. Of 717 specimens of blood cultured for fungi, 24 were positive; 12 samples were positive with both systems, 7 samples were positive with the Isolator system only, and 5 samples were positive with MYCO/F Lytic medium only. Fourteen samples grew Histoplasma capsulatum; both systems detected H. capsulatum in seven samples but the Isolator system alone detected H. capsulatum in seven samples. The mean times to the detection of H. capsulatum were 8 days (range, 4 to 13 days) for MYCO/F Lytic medium and 9 days (range, 6 to 18 days) for the Isolator system; the mean times to identification were 20 days (range, 15 to 24 days) for isolates recovered with MYCO/F Lytic medium and 11 days (range, 6 to 18 days) for those recovered with the Isolator system (P < 0.05). Cryptococcus neoformans was isolated from 10 fungal cultures; five isolates grew in both systems, and five isolates grew in MYCO/F Lytic medium only. The mean times to detection of C. neoformans were 4 days (range, 2 to 6 days) for MYCO/F Lytic medium and 7 days (range, 5 to 7 days) for the Isolator system (P < 0.05); the mean times to identification were 15 days (range, 7 to 27 days) for isolates recovered with MYCO/F Lytic medium and 8 days (range, 7 to 11 days) for those recovered with the Isolator system. Of the 687 samples of blood cultured for mycobacteria, 64 blood samples from 42 patients grew mycobacteria (58 grew Mycobacterium avium complex, 4 grew Mycobacterium kansasii, and 2 grew Mycobacterium tuberculosis); 42 isolates were recovered with both systems, 18 were isolated with MYCO/F medium only, and 4 were isolated with the ESP II system only alone (P < 0.05). The mean time to detection of mycobacteria with MYCO/F Lytic medium was 14 days, whereas it was 17 days with the ESP II system (P < 0.05). In summary, the combination of MYCO/F Lytic medium and the BACTEC 9240 instrument is an excellent blood culture system for the growth and detection of mycobacteria. A valid assessment of MYCO/F Lytic medium with regard to fungal isolation, however, was not possible due to the small number of isolates recovered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of BACTEC MYCO/F Lytic medium for recovery of mycobacteria, fungi, and bacteria from blood.

MYCO/F Lytic medium (MFL), a liquid medium developed for use with the BACTEC 9240 blood culture system, was compared to the Isolator system (IS) for the recovery of fungi and to the BACTEC 13A medium for the recovery of mycobacteria. Recovery of bacteria was compared to routine BACTEC Plus Aerobic/F (AF) blood cultures. Microbial growth was detected in 203 (17%) of 1,166 blood cultures. Fifty-s...

متن کامل

Evaluation of the efficacy of Myco/F lytic system, MGIT960 system and Lowenstein-Jensen medium for recovery of Mycobacterium tuberculosis from sterile body fluids

The diagnosis of extrapulmonary tuberculosis (EPTB) is challenging due to non-specific symptoms, invasive approach for specimen collection and most importantly, the paucibacillary status. The objective of this assay was to evaluate the efficacy of Myco/F lytic system, BACTEC Mycobacteria Growth Indicator Tube (MGIT) 960 system and Lowenstein-Jensen (L-J) medium for recovery of bacilli from ster...

متن کامل

Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.

To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube requi...

متن کامل

Comparison of MGIT and Myco/F lytic liquid-based blood culture systems for recovery of Mycobacterium tuberculosis from pleural fluid.

The specificities and sensitivities of the Bactec mycobacterial growth indicator tube (MGIT) system for the recovery of Mycobacterium tuberculosis from pleural fluid are not statistically different than those of the Myco/F lytic liquid culture system. The time to positivity is shorter in the MGIT system (12.7 versus 20.7 days, respectively; P=0.007). The Myco/F lytic culture system may be an al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 1998