Fluorescence Polarization Immunoassay, for Express Control of Antibiotic Levels: Design and Characteristics for Chloramphenicol, as an Example.
نویسندگان
چکیده
Characteristics of the fluorescence polarization immunoassay (FPIA) as a mean for express control of antibiotic levels in various specimens and its advantages vs. other analytical tests are described. The developmental stages of the analytical procedure and its parameters are considered for chlorampnenicol as an example. The analysis is based on competitive interaction of anti-chloramphenicol antibodies with the chloramphenicol-fluorophore conjugate and the potential free chloramphenicol in the specimen. The experimental results of the comparison of the chloramphenicol FPIA with the use of two conjugates differing in the length of the bridge length between the antibiotic functional groups and fluorophore (fluorescein) are presented. The requirements to the choice of the antibody and conjugate concentrations providing highly sensitive detection are characterized. The detection limit of chloramphenicol in the FPIA was 10 ng/ml and the determination of the concentrations ranged from 20 ng/mI to 10 mcg/ml. The time of the assay was 10 min.
منابع مشابه
Evaluation of an automated fluorescence polarization immunoassay for vancomycin.
An automated fluorescence polarization immunoassay for the determination of vancomycin levels in serum was evaluated. The vancomycin assay is a homogeneous competitive inhibition immunoassay based on changes in fluorescence polarization that occur with antibody binding. This assay was compared with a liquid chromatographic assay and an agar well diffusion bioassay method by using clinical serum...
متن کاملComparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.
We assayed serum gentamicin and tobramycin specimens by the enzyme multiplied immunoassay technique (Syva EMIT) and the fluorescence polarization immunoassay (Abbott TDx). When interassay and intraassay control samples were evaluated, both methods gave an overall coefficient of variation of less than +/- 10%. Using patient serum samples, we obtained excellent correlation with both methods in th...
متن کاملOptical Instruments for Fluorescence Polarization Immunoassays
The optical instruments which could be used for fluorescence polarization immunoassay (FPIA) were discussed. The theory of FPIAs and analytical applications for environmental and food control were presented.
متن کاملThe Effect of Chloramphenicol on Atropine and Scopolamine Contents in Datura Stramonium L.
Background & Aims: In regard to the importance of atropine and scopolamine as medicines with natural source, this study was aimed to investigate the effect of chloramphenicol as an inhibitor of protein synthesis on the alkaloids content of Datura stramonium. Method: After initial preparation of medicinal garden seeds, they were planted 50 cm apart in four different sections. Three different con...
متن کاملVancomycin Utilization Evaluation at Hematology-Oncology Ward of a Teaching Hospital in Iran
The aim of the present study was to evaluate the pattern of vancomycin administration in the hematology-oncology ward of Nemazee Hospital, Shiraz, Iran. Study criteria were developed to assess the several parameters involved in vancomycin therapy. These parameters include the appropriateness of drug usage, dosage, duration of therapy, monitoring for toxicity and serum concentration monitoring. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Antibiotiki i khimioterapiia = Antibiotics and chemoterapy [sic]
دوره 61 9-10 شماره
صفحات -
تاریخ انتشار 2016