[Initial experience with excimer laser-assisted pacemaker and defibrillator lead extraction].
نویسندگان
چکیده
Explantation of chronically implanted pacemaker or defibrillator leads can be technically demanding. We present the results of the first 44 leads extracted with excimer laser sheaths in 25 patients with a median lead implantation time of 7 years (range: 2 to 20 years). Indications for extraction were lead fracture in 17 patients, pocket infection in 4, septicemia in 2, and lead endocarditis in 2 cases. Complete extraction was achieved in 43 leads (97.7%), while the lead tip (< 4 cm) was abandoned in 1 case. There was no in-hospital mortality. The excimer laser-assisted system is a safe and efficient alternative for pacemaker and defibrillator lead extraction. This technology has resulted in excellent outcomes in our series, allowing us to treat remarkably difficult cases.
منابع مشابه
Initial experience in the extraction of chronically implanted pacemaker leads using the Excimer laser sheath.
OBJECTIVE To assess the safety and efficiency of the Excimer laser sheath in extracting chronically implanted pacemaker leads. PATIENTS Eight patients were studied (one female, mean age 62 years, range 34 to 77) with 17 pacemaker leads (five atrial, 10 ventricular, two implantable defibrillator). The mean implantation time was 65 months (range 23 to 188). The indications for lead extraction w...
متن کاملLaser assisted extraction of pacemaker and implantable defibrillator leads.
OBJECTIVE To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5+/-5.5 ye...
متن کاملDeaths and cardiovascular injuries due to device-assisted implantable cardioverter–defibrillator and pacemaker lead extraction
AIMS An estimated 10,000-15,000 pacemaker and implantable cardioverter-defibrillator (ICD) leads are extracted annually worldwide using specialized tools that disrupt encapsulating fibrous tissue. Additional information is needed regarding the safety of the devices that have been approved for lead extraction. The aim of this study was to determine whether complications due to device-assisted le...
متن کاملPacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial.
OBJECTIVES The purpose of this study was to evaluate the safety and effectiveness of pacemaker lead extraction with the excimer sheath in comparison to nonlaser lead extraction. BACKGROUND Fibrotic attachments that develop between chronically implanted pacemaker leads and to the venous, valvular and cardiac structures are the major obstacles to safe and consistent lead extraction. Locking sty...
متن کاملAn Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques
BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cardiologia
دوره 64 9 شماره
صفحات -
تاریخ انتشار 2011