Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively

نویسندگان

  • Emeline J. Ribot
  • Didier Wecker
  • Aurélien J. Trotier
  • Benjamin Dallaudière
  • William Lefrançois
  • Eric Thiaudière
  • Jean-Michel Franconi
  • Sylvain Miraux
  • Heye Zhang
چکیده

INTRODUCTION The purpose of this paper is to develop an easy method to generate both fat signal and banding artifact free 3D balanced Steady State Free Precession (bSSFP) images at high magnetic field. METHODS In order to suppress fat signal and bSSFP banding artifacts, two or four images were acquired with the excitation frequency of the water-selective binomial radiofrequency pulse set On Resonance or shifted by a maximum of 3/4TR. Mice and human volunteers were imaged at 7 T and 3 T, respectively to perform whole-body and musculoskeletal imaging. "Sum-Of-Square" reconstruction was performed and combined or not with parallel imaging. RESULTS The frequency selectivity of 1-2-3-2-1 or 1-3-3-1 binomial pulses was preserved after (3/4TR) frequency shifting. Consequently, whole body small animal 3D imaging was performed at 7 T and enabled visualization of small structures within adipose tissue like lymph nodes. In parallel, this method allowed 3D musculoskeletal imaging in humans with high spatial resolution at 3 T. The combination with parallel imaging allowed the acquisition of knee images with ~500 μm resolution images in less than 2 min. In addition, ankles, full head coverage and legs of volunteers were imaged, demonstrating the possible application of the method also for large FOV. CONCLUSION In conclusion, this robust method can be applied in small animals and humans at high magnetic fields. The high SNR and tissue contrast obtained in short acquisition times allows to prescribe bSSFP sequence for several preclinical and clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)

Purpose To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in 2π dephasing...

متن کامل

Improved shim method based on the minimization of the maximum off-resonance frequency for balanced steady-state free precession (bSSFP).

In this work, a shim method that minimizes the maximum off-resonance frequency (min-max shim) in balanced steady-state free precession (bSSFP) is tested for brain imaging at 3T with constant and linear shim terms. The method demonstrates improvement of spatial coverage and banding artifact reduction over standard least-squares shimming. In addition, a new method (modified min-max shim) is intro...

متن کامل

Increased Detectability of Alzheimer Plaques at 7T vs. 3T using High Resolution bSSFP

Introduction: β-amyloid plaques are thought to have an important role in the development and progression of Alzheimer’s disease (AD). Amyloid plaques are detectable at high-field as small hypointense regions in animal models [1] and ex vivo in human specimens [2], though in the latter case, clear separation of plaques from blood vessels remains an ongoing challenge. The underlying cause of the ...

متن کامل

Banding Artifact Reduction in 2D CINE Balanced SSFP at 3.0 T Using Phase-Cycling and k-t BLAST

Introduction Balanced steady-state free precession (bSSFP) offers excellent signal-to-noise ratio (SNR) and consistent blood/myocardium contrast which renders 2D CINE bSSFP an ideal clinical choice for LV function assessment [1] at 1.5 T. bSSFP imaging remains challenging at 3.0 T due to its sensitivity to adverse off-resonance effects induced by strong field inhomogeneities at the heart-lung i...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015