Marked reduction in internal atrial defibrillation thresholds with dual-current pathways and sequential shocks in humans.
نویسندگان
چکیده
BACKGROUND This study tested the ability of sequential shocks delivered through dual-current pathways to lower the atrial defibrillation threshold (ADFT) compared with a biphasic shock through a standard single-current pathway. METHODS AND RESULTS Electrodes were positioned in the right atrial appendage (RA), left subclavian vein (LSV), proximal coronary sinus (CSos), and distal coronary sinus (DCS) in 14 patients with chronic atrial fibrillation (170+/-185 days). Using a step-up protocol, we compared ADFTs for a single-current pathway (RA-->DCS) that used a single 7.5/2.5-ms biphasic shock from a 150-microF capacitor with those for a dual-current pathway system (RA-->DCS followed by CSos-->LSV) using sequential 7.5/2.5-ms biphasic shocks with capacitor discharge waveforms for 150-microF and 600-microF capacitors. Both dual-current pathway configurations (2.0+/-0.4 J for 150-microF capacitance, 2.4+/-0.5 J for 600-microF capacitance) had a significantly lower ADFT than the single-current pathway (5.1+/-1.8 J). Whereas the dual-current pathway with 150-microF capacitor shocks had a significantly lower energy threshold, there was no statistical difference in terms of leading-edge voltage compared with the dual-current pathway with 600-microF capacitance shocks. There were no ventricular arrhythmias induced with appropriately synchronized shocks. CONCLUSIONS For internal atrial defibrillation in humans, sequential biphasic waveforms delivered over dual-current pathways resulted in a markedly reduced (>50% reduction) ADFT compared with a single shock over a single-current pathway.
منابع مشابه
Marked reduction in atrial defibrillation thresholds with repeated internal cardioversion.
OBJECTIVES This study was performed to assess the atrial defibrillation threshold in patients with recurrent atrial fibrillation (AF) using repeated internal cardioversion. BACKGROUND Previous studies in patients with chronic AF undergoing internal cardioversion have shown this method to be effective and safe. However, current energy requirements might preclude patients with longer-lasting AF...
متن کاملAtrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.
OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...
متن کاملComparison of single- and dual-coil active pectoral defibrillation lead systems.
OBJECTIVES The purpose of this study was to compare defibrillation thresholds with lead systems consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Lead systems that include an active pectoral pulse generator reduce defibrillation thresholds and permit transvenous defibrillation in nearly all patients. A further improvement in defibrillation...
متن کاملImproved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms.
A reduction in the shock strength required for defibrillation would allow use of a smaller automatic implantable cardioverter-defibrillator and would reduce the possibility of myocardial damage by the shock. Most internal defibrillation electrodes require 5 to 25 J for successful defibrillation in human beings and in dogs. In an attempt to lower the shock strength needed for defibrillation, we ...
متن کاملExtended charge banking model of dual path shocks for implantable cardioverter defibrillators
BACKGROUND Single path defibrillation shock methods have been improved through the use of the Charge Banking Model of defibrillation, which predicts the response of the heart to shocks as a simple resistor-capacitor (RC) circuit. While dual path defibrillation configurations have significantly reduced defibrillation thresholds, improvements to dual path defibrillation techniques have been limit...