Stability of plasma electrolytes in Barricor and PST II tubes under different storage conditions

نویسندگان

  • Luis Alfredo Bautista Balbás
  • Marta Segovia Amaro
  • Rubén Gómez Rioja
  • María José Alcaide Martín
  • Antonio Buńo Soto
چکیده

INTRODUCTION Sample stability can be influenced by many different factors; evaporation and leakage from residual cells are the most relevant factors for electrolytes. During the analytical phase, samples are usually kept uncapped at room temperature. Once samples are processed, they are usually stored sealed and refrigerated. Long turnaround time and the possibility of "add-on test" need consideration for electrolyte stability. The aim of our study is to examine short-term electrolyte stability in this two-common laboratory working conditions in two different lithium heparin plasma tubes (Barricor and PST II, Becton Dickinson). MATERIALS AND METHODS In 39 plasma samples from voluntary subjects we measured sodium (Na+), potassium (K+) and chloride (Cl-) at 6 time points since centrifugation (0h, 3h, 6h, 9h, 12h and 15h). Maximum allowable bias (clinically significant change) was based in SEQC (Sociedad Espańola de Química Clínica) recommendations; 1% for Cl-, 0.6% for Na+ and 4% for K+. RESULTS In open room temperature tubes, clinically significant changes appeared in Na+ and Cl- after 3 hours and in K+ after 9 hours in both types of tubes. In refrigerated sealed tubes, all the analytes were clinically stable up to 12 hours in both kinds of plasma tubes. We observed a statistically significant progressive increase in K+ levels, which was less pronounced in Barricor tubes. CONCLUSION Stability of electrolytes is compromised after 3 hours in open tubes and after 12 hours in sealed tubes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes

Introduction Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. Materials and methods We coll...

متن کامل

The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube

INTRODUCTION Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. MATERIALS AND METHODS Samples from 44 volunt...

متن کامل

Germination and viability coefficients of Faba Bean (Vicia faba) seed under different storage conditions

Extended Abstract Introduction: Pulses are among the best sources of plant protein and important components of crop rotation, which in recent years, have been considered one of the major options for plant research. Seed storage is one of the important traits in legume breeding. Storage temperature, seed moisture content, and storage duration are the most important factors affecting seed qualit...

متن کامل

Quantification of Plasma or Serum Short-Chain Fatty Acids: Choosing the Correct Blood Tube

Background: Short-Chain Fatty Acids (SCFA; acetate, propionate and butyrate) are more and more recognised as mediators of local gut and systemic health. Quantification of SCFA in plasma and serum is challenging due to their low concentrations in human blood and the ubiquitous nature of acetate, requiring careful standardisation of the sample preparation procedure. Also the choice of the blood t...

متن کامل

Stability of plasma human immunodeficiency virus load in VACUTAINER PPT plasma preparation tubes during overnight shipment.

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas obtained from PPT tubes stored and shipped under nine different conditions were compared to conventional EDTA tube plasmas stored at -70 degrees C within 2 h after phlebotomy. Compared to viral loads...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2017