Inflammation at the insertion site is not predictive of catheter-related bloodstream infection with short-term, noncuffed central venous catheters.

نویسندگان

  • Nasia Safdar
  • Dennis G Maki
چکیده

BACKGROUND Noncuffed, percutaneously inserted central venous catheters (CVCs) are widely used and cause at least 250,000 bloodstream infections (BSIs) in U.S. hospitals each year. We report a prospective study to determine whether inflammation at the insertion site is predictive of CVC-related BSI. METHODS Percutaneously inserted, noncuffed CVCs inserted into the subclavian, internal jugular, or femoral vein in two randomized trials during 1998-2000 were prospectively studied; most patients were in an intensive care unit. The condition of the insertion site was evaluated daily by research nurses, quantifying pain (0, 1), erythema (0-2), swelling (0, 1), and purulence (0, 1); the lowest possible overall inflammation score was 0 and the highest was 5. CVC-related BSI was confirmed in each case by demonstrating concordance between isolates from the catheter segment and from blood cultures by restriction-fragment DNA subtyping. RESULTS Among 1,263 CVCs prospectively studied, 333 (26.3%) were colonized at removal; of these, 35 catheters (2.7%) caused BSIs (5.9 per 1000 CVC days). BSIs were caused by coagulase-negative staphylococci (n = 27), enterococci (n = 4), enteric Gram-negative bacilli (n = 3), or (n = 1). Most insertion sites showed little or no inflammation at the time of removal. There were no significant differences among mean scores for each inflammatory variable examined or overall score among colonized CVCs (0.1 +/- 0.1), catheters causing CVC-related BSI (0.2 +/- 0.4), and noncolonized CVCs (0.1 +/- 0.1). The sensitivity of local inflammation for diagnosis of CVC-related BSI was dismal (0-3%). CONCLUSION Local inflammation is uncommon with infected CVCs, probably because most catheter-associated infections are currently caused by coagulase-negative staphylococci, a pathogen that incites little local or systemic inflammation. Whereas overt inflammation of the insertion site should raise suspicion of CVC-related BSI caused by or Gram-negative bacilli, especially if the patient has fever or other signs of sepsis, in general, site appearance cannot be relied on to identify catheter colonization or CVC-related BSI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter. A randomized, controlled trial.

BACKGROUND Bloodstream infection related to short-term use of noncuffed central venous catheters is a common and serious problem. Technologic innovations to reduce the risk for these infections are needed. OBJECTIVE To determine 1) the efficacy of a novel antiseptic catheter in preventing central venous catheter-related infection, 2) patient tolerance of this catheter, and 3) the sources of b...

متن کامل

Review of recommendations to prevent and reduce catheter-related bloodstream infections

ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...

متن کامل

The promise of novel technology for the prevention of intravascular device-related bloodstream infection. I. Pathogenesis and short-term devices.

Intravascular devices (IVDs) are widely used for vascular access but are associated with substantial risk of development of IVD-related bloodstream infection (BSI). The development of novel technologies, which are based on an understanding of pathogenesis, promises a quantum reduction in IVD-related infections in an era of growing nursing shortages. Infections of short-term IVDs (that is, those...

متن کامل

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies.

OBJECTIVE To better understand the absolute and relative risks of bloodstream Infection (BSI) associated with the various types of intravascular devices (IVDs), we analyzed 200 published studies of adults In which every device in the study population was prospectively evaluated for evidence of associated infection and microbiologically based criteria were used to define IVD-related BSI. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 30 12  شماره 

صفحات  -

تاریخ انتشار 2002