Excision of the donor cornea instead of enucleation.

نویسنده

  • S Vannas
چکیده

Shortage of corneal grafts is common in many countries. The method presented here has been developed to relieve this situation and make it easier, especially from the psychological point of view, to obtain a license for excising corneas from cadavers. An 11 mm. corneal button is excised from the donor eye in situ with a Draeger electric rotor trephine and the donor eyes remain apparently normal looking. These excised corneas without sclerocorneal rims are placed in adequate without sclerocorneal rims are placed in adequate storage media for long-term cryopreservation according to Capella, Kaufman, and Robbins or for short-term storage according to McCarey and Kaufman. The preliminary results are promising and the technique seems not to be too delicate or complicated to be carried out by an experienced eye bank technician. It has improved our possibilities for storing donor corneas and for collecting many tissue-typed corneas in our eye bank.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of in situ Corneoscleral Disc Excision versus Whole Globe Enucleation in Cornea Donors Regarding Microbial Contamination in Organ Culture Medium - a Prospective Monocentric Study over 9 Years.

BACKGROUND CORNEAS NEEDED FOR KERATOPLASTY CAN BE HARVESTED USING TWO TECHNIQUES: whole globe enucleation and in situ excision of the corneoscleral disc. This study evaluates the rate of microbial contamination of the donor cornea organ culture medium according to the method of retrieval. METHODS All donor corneas of our cornea bank received between January 1, 2001 and December 31, 2009 put i...

متن کامل

Donor risk factors for graft failure in the cornea donor study.

PURPOSE The purpose of this study was to assess the relationship between donor factors and 5-year corneal graft survival in the Cornea Donor Study. METHODS Donor corneas met criteria established by the Eye Bank Association of America, had an endothelial cell density of 2300 to 3300/mm, and were determined to be of good to excellent quality by the eye banks. Donor corneas were assigned using a...

متن کامل

[Comparative analysis of the donor cornea quality and of the interval between death and preservation before and after new sanitary and technique rules in a University Eye Bank].

PURPOSE To compare the interval between death and enucleation (ΔT-O-E), between enucleation and preservation (ΔT-E-P) and the quality of the cornea before and after the implantation of new technique and sanitary rules. METHODS A retrospective study that evaluated the records of cornea donors in Sao Paulo's Santa Casa Eye Tissue Bank 2 years before and 2 years after the implementation new sani...

متن کامل

P 180 Post-mortem time and discard rate of human donor corneas

Purpose: The authors report the results of more lhan 150 cases of long term culture for comeal storage at 31 'C. hWmds : An enucleation procedure is done before comeoscleral removal in the labixatory.under laminar flow hood.The media used are INOSOL and EXOSOL from OPSIA Endothelium evaluation is performed under microscope. Resuls : 25% of the wmeas are rejected from transplantation because of ...

متن کامل

P 182 Secondary implantation with open loop intra ocular lens in the anterior chamber versus scleral sutured posterior chamber lens during penetrating keratoplasty (PK)

Purpose: The authors report the results of more lhan 150 cases of long term culture for comeal storage at 31 'C. hWmds : An enucleation procedure is done before comeoscleral removal in the labixatory.under laminar flow hood.The media used are INOSOL and EXOSOL from OPSIA Endothelium evaluation is performed under microscope. Resuls : 25% of the wmeas are rejected from transplantation because of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 1975