Effective Doses and Organ Doses per Unit Fluence Calculated for Monoenegetic 0.1 to 100MeV Electrons by the MIRD-5 Phantom

نویسندگان

  • M. Katagiri
  • M. Hikoji
  • M. Kitaichi
  • S. Sawamura
چکیده

To determine quantities for radiation protection against high-energy electrons, such as those from LINAC, the organ dose equivalents and equivalent doses for the human body were calculated using EGS-4 Monte Carlo simulation code and an MIRD-5 mathematical human phantom. Conversion factors for the incident fluence to the organ dose equivalent, to the effective dose and to the effective dose equivalent for monoenergetic electrons were obtained for AP and PA geometrical irradiation conditions at incident energies from 0.1 to 100MeV. The agreement between the results of the present study of effective doses and those of other studies was acceptable within the statistical uncertainties. At energies lower than 10MeV, the skin sensitive layer was taken into account in some computations. It was found that the effective doses depend on the incident electron energy, beam size, and exposure position of the body.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry

We modified the Imaging Performance Assessment of CT scanners (ImPACT) to evaluate the organ doses and the effective dose based on the International Commission on Radiological Protection (ICRP) Publication 110 reference male/female phantom with the Aquilion ONE ViSION Edition scanner. To select the new CT scanner, the measurement results of the CTDI100,c and CTDI100,p for the 160 (head) and the...

متن کامل

New calculations for internal dosimetry of beta-emitting radiopharmaceuticals.

The calculation of absorbed dose from internally incorporated radionuclides is based on the so-called specific absorbed fractions (SAFs) which represent the fraction of energy emitted in a given source region that is absorbed per unit mass in a specific target organ. Until recently, photon SAFs were calculated using MIRD-type mathematical phantoms. For electrons, the energy released was assumed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000