Liquid chromatographic determination of residual nitrite/nitrate in foods: NMKL collaborative study.

نویسندگان

  • L Merino
  • U Edberg
  • G Fuchs
  • P Aman
چکیده

Nitrite and nitrate are used as additives in the food industry to provide color and taste and to control undesirable gas and flavor production by anaerobic bacteria by virtue of their antimicrobial properties. The analytical method that has been widely used to determine nitrite and nitrate involves the use of toxic cadmium. In response to a request from the Nordic Committee on Food Analysis, a study was performed to obtain an alternative chromatographic method to determine residual nitrite and nitrate in meat products. The study was done in 3 stages: (1) comparative evaluation of the performance of 3 liquid chromatographic methods, (2) internal validation of the selected ion chromatographic method, and (3) a collaborative study in which 17 laboratories from European countries participated. Furthermore, the applicability of the method to matrixes other than meat and meat products was demonstrated. The results of the collaborative study show that the European Prestandard prENV 12014-4 is well suited for the determination of nitrite and nitrate in different foods (e.g., meat products, vegetables, baby food, and cheese). The limits of detection for nitrite and nitrate ions are 1 and 10 mg/kg, respectively. Recoveries of residual nitrite/nitrate ranged from 96 to 108%. Repeatability and reproducibility were satisfactory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of cholecalciferol (vitamin D3) in selected foods by liquid chromatography: NMKL collaborative study.

Results are presented from an NMKL (Nordic Committee on Food Analysis) collaborative study of a method for the determination of cholecalciferol (vitamin D3) in foods. The method is based on the addition of an internal standard (vitamin D2), followed by saponification and extraction with n-heptane. The fraction that contains vitamin D2/D3 is separated by preparative normal-phase liquid chromatog...

متن کامل

A Review of Nitrate and Nitrite Toxicity in Foods

Agricultural advancement and population growth have prompted increases in food supplies, and higher crop yields have been made possible through the application of fertilizers. Large quantities of livestock and poultry on farms, along with the accumulation of biomass and agricultural residues, can cause contamination of ground water resources and other water sanitation concerns in both developin...

متن کامل

اندازه گیری باقیمانده نیترات و نیتریت سدیم در فرآورده‌های گوشتی تولیدی بعضی از شهرهای استان مازندران در نیمه دوم‌ سال 1387

Background and purpose: Nitrate and nitrite salts to prevent the growth of Çlostridium specie can be added to meat products.Âccording to carcinogenetic properties of this ions, aim of this study was to measurement of nitrate and nitrite content in meat product in Mazandaran. Materials and methods: Â cross sectional study on 42 sample of red Meat Products (sausages with 40% and 60% meat, ha...

متن کامل

Determination of nitrate by suppressed ion chromatography after copperised-cadmium column reduction.

The nitrate-selective copperised-cadmium (Cu-Cd) reduction reaction coupled directly to the highly sensitive nitrite ion chromatographic detection, produced a more precise method for determination of nitrate than any one of the two conventional methods. A borate buffer solution used in the reduction reaction, in place of the conventional ammonium-EDTA buffer solution, eliminated interferences f...

متن کامل

Simultaneous Determination of Nitrite and Nitrate by Ultra-performance Liquid Chromatography in Rat Plasma

Objective: To develop an ultraperformance liquid chromatography (AcquityTM UPLC) method for simple, fast, accurate and simultaneous determination of nitrite and nitrate ions as stable forms of nitric oxide (NO) production in rat plasma. Methods: The ion-pairing AcquityTM UPLC method with reverse phase BEH C18 column was used along with photodiode array (PDA) UV-Vis detector to separate and dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 83 2  شماره 

صفحات  -

تاریخ انتشار 2000