Effectiveness of Hot Aerosol Extinguishing Agent in Suppressing Oil Fires at Different Locations

نویسندگان

  • W. - F. Zheng
  • A. - H. Liu
  • L. Zhang
  • Q. - W. Li
  • X. - Y. Lin
  • R. - M. Pan
چکیده

As a suitable candidate for the next halon alternative gaseous fire-extinguishing agent, it is very meaningful to investigate how to improve the fire-extinguishing capacity of hot aerosol fire extinguishing agents for local fires. When fire breaks out, the actual fire location is unpredictable, and the extinguishing efficiency of hot aerosol extinguishing agent will be observably affected by the fire locations due to different flame patterns and intensities at different fire locations. In this work, the use of the hot aerosol extinguishing agent in suppressing oil fires at different locations, including open, partially open, and fully closed locations, has been investigated in order to obtain the regularity of the effectiveness of the hot aerosol extinguishing agent in suppressing a local fire. The results have shown that the hot aerosol extinguishing agent is more effective in suppressing an oil fire in a fully closed system than in an open system or partially open system. The shortest fire-extinguishing time was for the fire in the corner, followed by the one in the middle, and the fire against the wall took the longest time to extinguish for fire locations in a partially open system and a fully closed system, respectively. In addition, the fire extinguishing process involves varying degrees of flame enhancements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Aerosol Fire Extinguishing Agent Using a Simple Diffusion Model

Aerosol fire extinguishing agents have been recognized as an effective replacement of Halon. The uniform diffusion time and the effective concentration of the aerosol fire extinguishing agent are important parameters for putting out a fire. In this work, the effective concentration is derived based on the diffusion equation, and its variation with changing diffusion coefficient and diffusion ti...

متن کامل

Review on Water Mist Fire Suppression System

Water mist fire suppression system (WMFSS) is one of the candidates in substituting the Halogen-based total flooding system. The system with strong spray momentum gives a satisfactory performance in extinguishing solid fires, liquid fires as well as kitchen fires under no ventilation. Nozzle with high discharge momentum and low operating pressure are the goal. Water mist discharged is assumed t...

متن کامل

Application of fourier transform infrared (FTIR) spectroscopy to investigate the degradation of cooking oils during fire suppression

Introduction Auto-ignition of cooking oils causes a significant proportion of household fires [1,2]. In addition, the majority of the 50% of all accidental fires in hotels, restaurants and fast food outlets that start in kitchens involve liquid cooking oil or fat as the primary ignition source [3,4]. The potential risk of loss of life and property damage due to cooking oils fires is high. Cooki...

متن کامل

Visualization of hot flows of tall space fires in model experiments with Schlieren Photography technique

The natural smoke exhaust system for tall spaces is more advantageous than the mechanical type of exhaust. In Taiwan, the effectiveness of natural smoke exhaust systems is inspected only by checking the vent area size. However, the air flow field in a tall space is very complicated, both at ordinary times or during fires. This study used Schlieren Photography technique, on the principle that li...

متن کامل

Metal Signature of Atmospheric Aerosol from Kochi, the Queen of Arabian Sea, Kerala, India

The present research article highlights the metal (Cd, Cu, Pb, Zn and Fe)distribution pattern in the RSPM generated in different hot spot sites located at Kochi, theQueen of Arabian Sea. These sampling sites are categorized under three different zonesas estuarine, riverine, and coastal. Two sampling phases are selected in order to check theconsistency in pollution trend after a two year gap and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016