Evaluation of culture and the Gen-Probe PACE 2 assay for detection of Neisseria gonorrhoeae and Chlamydia trachomatis in endocervical specimens transported to a state health laboratory.

نویسندگان

  • R J Limberger
  • R Biega
  • A Evancoe
  • L McCarthy
  • L Slivienski
  • M Kirkwood
چکیده

The Gen-Probe PACE 2 assay (Gen-Probe Inc., San Diego, Calif.) was compared with culture for the detection of Neisseria gonorrhoeae in endocervical specimens that were mailed to the laboratory. During mail transport, the specimens were exposed to extremes of hot and cold weather for several days before arriving in the laboratory. Specimens on culture plates deteriorated during transport, as evidenced by many dead gonococcus-like colonies. The manufacturer's recommendation for reporting PACE 2 assay-positive results was modified to create a suspicious category for samples with relative light units near the positive cutoff value. Of a total of 4,869 specimens tested, 30 were positive by both methods and 102 were positive only by the PACE 2 assay. These additional 102 positive specimens were likely to be true positives, as indicated by several lines of indirect evidence, including detailed probe competition analysis, patient history, and the lack of false-positive results in hand-delivered specimens. Although Gen-Probe Inc. indicates that specimens are stable for up to 7 days, N. gonorrhoeae was easily detectable by the PACE 2 assay after 1 month of incubation at room temperature in the PACE 2 transport buffer. We also compared the Gen-Probe PACE 2 assay for Chlamydia trachomatis with culture on endocervical specimens delivered by same-day courier. Of 398 endocervical specimens tested, the PACE 2 assay detected 19 of 20 culture-positive samples. Although the assay failed to detect one culture-positive sample, it was able to detect two very weak culture-suspicious samples. Finally, PACE 2 assays for N. gonorrhoeae and C. trachomatis performed on the same samples indicated that the coinfection rate was 40% for women attending five family planning clinics. We concluded that the Gen-Probe PACE 2 assay system should be considered for use in testing those specimens that are transported to the laboratory through the mail.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of chlamydiazyme, PACE 2, and AMP-CT assays for detection of Chlamydia trachomatis in endocervical specimens.

We conducted a comparative evaluation of the Chlamydiazyme (Abbott Laboratories), PACE 2 (Gen-Probe), and AMP-CT (Gen-Probe) assays for the detection of Chlamydia trachomatis in endocervical samples. Specimens from 787 females were included in the study. The sensitivities of the PACE 2 and Chlamydiazyme assays in comparison to the results of the AMP-CT assay were 79.3 and 63.4%, respectively. T...

متن کامل

Use of gen-probe probe competition assay as a supplement to probes for direct detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urogenital specimens.

The potential for development of a cost-effective protocol for selective use of the Gen-Probe probe competition assay (PCA) in conjunction with PACE 2 for direct detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urogenital specimens that would not compromise patient care was investigated. To accomplish this, PCA data from testing performed over 12 months were retrospectively revie...

متن کامل

Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, ...

متن کامل

Evaluation of COBAS AMPLICOR (Roche): accuracy in detection of Chlamydia trachomatis and Neisseria gonorrhoeae by coamplification of endocervical specimens.

We evaluated further the accuracy of the COBAS AMPLICOR (Roche) (CA) PCR-based system in detection of Chlamydia trachomatis and Neisseria gonorrhoeae in endocervical specimens. Endocervical specimens collected for any indication for testing for C. trachomatis and N. gonorrhoeae among a university hospital health system population were included. Testing for C. trachomatis was done by two PCR met...

متن کامل

COMPARISON OF PCR BASED ASSAY AND CELL CULTURE IN DETECTION OF UROGENITA L CHLAMYDIA TRACHOMATIS INFECTION AND DETERMINATION OF THE INHIBITORY RATE O F SPECIMENS UNDER STUDY

An amplification polymerase chain reaction (PCR) test for the direct detection of Chlamydia trachomatis in urethral and endocervical swab specimens from symptomatic and asymptomatic women and men were compared to standard culture technique. During 6 months, 300 endocervical swab specimens from 205 asymptomatic women (64.4%) and 95 symptomatic women (31.6%), and 187 urethral swab specime...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 1992