Degenerative processes in bioprosthetic mitral valves in juvenile pigs

نویسندگان

  • Jesper L Honge
  • Jonas A Funder
  • Torben B Pedersen
  • Mads B Kronborg
  • J Michael Hasenkam
چکیده

BACKGROUND Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthetic valve complications in the mitral position in juvenile pigs. MATERIALS The study material comprised eight, 5-month old, 60-kg pigs. All pigs received a size 27, glutaraldehyde-treated, stented, Carpentier-Edwards S.A.V. mitral valve prosthesis. After six months, echocardiography was performed, and the valves explanted for gross examination, high resolution X-ray, and histological evaluation. RESULTS Five pigs survived the follow-up period. Preexplant echocardiography revealed a median peak and mean velocity of 1.61 m/s (range: 1.17-2.00) and 1.20 (SD = ±0.25), respectively, and a median peak and mean pressure difference of 10.42 mmHg (range: 5.83-16.55) and 6.51 mmHg (SD = ±2.57), respectively. Gross examination showed minor thrombotic depositions at two commissures in two valves and at all three commissures in three valves. High resolution X-ray imaging revealed different degrees of calcification in all explanted valves, primarily in the commissural and belly areas. In all valves, histological evaluation demonstrated various degrees of fibrous sheath formation, limited immunological infiltration, and no overgrowth of host endothelium. CONCLUSIONS Bioprosthetic glutaraldehyde-treated mitral valves can be implanted into the mitral position in pigs and function after 6 months. Echocardiographic data, calcification, and histological examinations were comparable to results obtained in sheep models and human demonstrating the suitability of the porcine model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recellularization of decellularized mitral heart valves in juvenile pigs.

BACKGROUND AND AIM OF THE STUDY Glutaraldehyde-preserved bioprosthetic heart valves are non-viable and have a limited durability because of calcification, tissue wear, and inflammation, especially in children. Decellularized porcine heart valves, when treated with deoxycholic acid (DOA), have exhibited complete recellularization and an absence of calcification when implanted into the pulmonary ...

متن کامل

Frequency of the first heart sound in the assessment of stiffening of mitral bioprosthetic valves.

The frequency spectrum of the first heart sound (S1) was measured noninvasively in 54 patients with porcine bioprosthetic valves inserted in the mitral position. Phonocardiograms were recorded on magnetic tape on line with a signal processor with which the frequency spectrum and peak frequency of S1 were determined. In 19 patients with normal natural mitral valves, the apparent peak frequency w...

متن کامل

Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.

BACKGROUND AND AIM OF THE STUDY The performance and longevity of bioprosthetic heart valves are limited by tissue calcification and degeneration after implantation. Experimental valve replacement in large animal models forms an important component of the preclinical evaluation of these bioprosthetic heart valves. The study aim was to assess the feasibility of a mitral model for stentless valves...

متن کامل

Implantation of mitral, aortic, and tricuspid bioprostheses due to infective endocarditis with necessary reimplantation of the bioprosthetic aortic valve

The patient was admitted to the Department of Cardiac Surgery of the J. Struś City Hospital in Poznan due to infective endocarditis involving the aortic, mitral, and tricuspid valves. Implantation of three biological valve prostheses proceeded without complications. Starting on day 23, the patient's general condition deteriorated, with high fever. Despite postoperative antibiotic therapy, trans...

متن کامل

Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011