Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging
نویسندگان
چکیده
BACKGROUND We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and good repeatability for regional MBF and CFR values. The results will have significant impact on cardiac PET imaging in terms of making it more affordable and increasing its use. METHODS 12 normal volunteers were imaged at rest and during pharmacological stress, with 2220 MBq of 82Rb each. A GE Advance PET system was used to acquire dynamic 50-frame studies. MBF was calculated with a 2-compartmental model using a modified PMOD program (PMOD; University Hospital Zurich, Zurich, Switzerland). Two differential equations, describing a 2-compartmental model, were solved by numerical integration and using Levenberg-Marquardt's method for fitting data. The PMOD program defines 16 standard segments and calculates myocardial flow for each segment, as well as average septal, anterior, lateral, inferior and global flow. Repeatability was evaluated according to the method of Bland and Altman. RESULTS Global rest and stress MBF, as well as global CFR, showed very good repeatability. No significant differences were found between the paired resting global MBF (0.63 +/- 0.13 vs. 0.64 +/- 0.13 mL/min/g; mean difference, -1.0% +/- 2.6%) and the stress global MBF (1.37 +/- 0.23 vs. 1.37 +/- 0.24; mean difference, 0.1% +/- 2.3%). Global CFR was highly reproducible (2.25 +/- 0.56 vs. 2.22 +/- 0.54, P = not statistically significant; mean difference, 1.3% +/- 14.3%). Repeatability coefficients for global rest MBF were 0.033 (5.2%) and stress MBF 0.062 (4.5%) mL/min/g. Regional rest and stress MBF and CFR have shown good reproducibility. The average per sector repeatability coefficients for rest MBF were 0.056 (8.5%) and stress MBF 0.089 (6.3%) mL/min/g, and average repeatability coefficient for CFR was 0.25 (10.6%). CONCLUSION The results of the study show that software calculation of MBF and CFR with 82Rb myocardial PET imaging is highly repeatable for global values and has good repeatability for regional values.
منابع مشابه
Repeatability of rest and hyperemic myocardial blood flow measurements with 82Rb dynamic PET.
UNLABELLED The repeatability of rest and hyperemic myocardial blood flow (MBF) measurements using 82Rb PET has not been evaluated. The aim of this study was to investigate the short-term repeatability of such measurements. METHODS Fifteen healthy volunteers underwent rest and pharmacologic stress 82Rb PET, repeated 60 min apart. RESULTS There was no significant difference in repeated rest M...
متن کاملOptimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET
Purpose. Myocardial blood flow (MBF) quantification with 82Rb positron emission tomography (PET) is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic 82Rb PET, from which MBF was quan...
متن کاملNoninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model.
Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...
متن کاملNoninvasive Quantification of Regional Myocardial Perfusion With Rubidium-82 and Positron Emission Tomography
Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...
متن کاملCardiac PET/CT with Rb-82: optimization of image acquisition and reconstruction parameters
BACKGROUND Our aim was to characterize the influence of time-of-flight (TOF) and point spread function (PSF) recovery corrections, as well as ordered subset expectation maximization (OSEM) reconstruction parameters, in 82Rb PET/CT quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Rest and stress list-mode dynamic 82Rb PET acquisition data from 10 patients without ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Medical Physics
دوره 9 شماره
صفحات -
تاریخ انتشار 2009