Tension and fatigue behavior of 316LVM 1x7 multi-strand cables used as implantable electrodes.
نویسندگان
چکیده
The mechanical behavior of 316LVM 1x7 cables were evaluated in uniaxial tension, and in cyclic strain-controlled fatigue with the use of a Flex tester operated to provide fully reversed bending fatigue. The magnitude of cyclic strains imparted to each cable tested was controlled via the use of different diameter mandrels. Smaller diameter mandrels produced higher values of cyclic strain and lower fatigue life. Multiple samples were tested and analyzed via scanning electron microscopy. The fatigue results were analyzed via a Coffin-Manson-Basquin approach and compared to fatigue data obtained from the literature where testing was conducted on similar materials, but under rotating bending fatigue conditions.
منابع مشابه
Mechanical behaviour of implantable electrodes
A team of materials scientists is supporting the development of Networked Implantable Neuroprostheses (NNPS) Systems on an NIHBioengineering Research Partnership. The Materials Group is leading the material and structural evaluation, analysis, and testing of implantable electrodes and interconnects that form part of the NNPS. Currently the potential use of silver cored Drawn Filled Tube (DFT) c...
متن کاملDamage Detection in Post-tensioned Slab Using 2D Wavelet Transforms
Earthquake force, loading more than structural capacity, cracking, material fatigue and the other unpredicted events were undeniable in the structure life cycle in order that environmental conditions of the structure would be changed and treats health. Damage of structures such as crack, corrosion of the post tension cables from inappropriate grouting of the post tension structures and etc. can...
متن کاملDynamic Analysis of Moving Cables with Variable Tension and Variable Speed
Dynamic Analysis of an axially moving cable with time dependent tension and velocity isstudied in this paper. Tension force and the moving speed are assumed to be harmonic.It is found that there exists a specific value of speed in which natural frequency of the system approacheszero. This specific speed for such a critical condition is called critical speed and it will be proved thatincreasing ...
متن کاملCumulative Fatigue Damage Under stepwise Tension-Compression Loading
Rock structures are subjected to cyclic tension-compression loading due to a blasting, earthquake, traffic and injection-production in underground storage case. Therefore study the fatigue behavior of rock samples under this type of loading is required. In this study, the accumulated fatigue damage for a Green Onyx rock sample which consisted of only one mineral composition with two-step high-l...
متن کاملDevelopment of a New Implantable System for Functional Electrical Stimulation in Sendai Fes Project
We developed a new implantable FES system with 32 output channels. In this system, a RF coil utilizing amorphous magnetic fibers was introduced for increasing transmission efficiency of this telemeter system which transmitted currents for electric power supply to the implanted system and for applying electrical stimulation to the paralyzed muscles. A helically coiled 19 strand rope wound from u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Materials science & engineering. A, Structural materials : properties, microstructure and processing
دوره 486 1-2 شماره
صفحات -
تاریخ انتشار 2008