Effect of atropine on alveolar gas mixing in man.
نویسندگان
چکیده
1. Atropine is known to diminish bronchomotor tone. In order to investigate the acute effect of atropine on respiration and alveolar gas mixing, a dose of 2.4 mg was given intravenously. 2. Ten normal male volunteers were each studied three times with a nitrogen washout method, once before administration of atropine and then 20 min and 60 min thereafter. 3. After the administration of atropine there was a reduction in tidal volume, a slight increase in frequency of respiration and an increase in series dead space. The tidal mixing volume showed a fall of 25%. In spite of the reduced alveolar dead space the effective mixing volume fell by 29%. Multi-breath alveolar mixing efficiency fell by 3.5%. 4. Multi-breath alveolar mixing efficiency was found to be less with smaller tidal mixing volumes, a fall of 518 ml in the latter causing a reduction of 17.2% in mixing efficiency. 5. A reduction of 100 ml in tidal volume in normal subjects was associated with a decrease of 6.9% in alveolar mixing efficiency. In the subjects receiving atropine tidal volume reduced by 96 ml, but the observed fall in alveolar mixing efficiency was only 3.5%, This suggests an improvement in alveolar mixing of 3.4% due to the administration of atropine. Despite this small improvement, the mixing efficiency is still only 66%. The residual inefficiency of 34% cannot therefore be explained on the basis of bronchomotor tone.
منابع مشابه
Effect of Novel Swirl Distributor Plate on Hydrodynamics of Fluidized Bed Gasifier
The main advantage of a fluidized bed is its capability in excellent gas-fuel mixing. However, due to the lacks of gas radial momentum, its lateral mixing of gas-solid is not adequate. Therefore, this research is focused on fluidized bed hydrodynamics enhancement using the modified gas distributor plate design. For getting an optimum fluidized bed hydrodynamics prediction, three different class...
متن کاملMixing Studies in Loop Bioreactors for Production of Biomass from Natural Gas
The mixing behavior of the gas-liquid phase in three loop bioreactors was investigated. A gas-induced External Airlift Loop Bioreactor (EALB), a forced-liquid Vertical Tubular Loop Bioreactor (VTLB) and a forced-liquid Horizontal Tubular Loop Bioreactor (HTLB) were used for mixing studies as well as biomass production from natural gas. The effect of design parameters, riser to downcomer cro...
متن کاملEffects of NO2 on chronic bronchitics.
The acute influence of NO2 on mechanics of breathing and respiratory gas exchange was investigated in a total of 111 subjects, aged 25 to 74 years, with chronic nonspecific lung disease (CNSLD). They breathed NO2-air mixtures containing 0.5 to 8.0 ppm NO2 for up to 15 to 60 min. Additionally in nine subjects the protective action of atropine, meclastine, and orciprenaline was investigated. Whil...
متن کاملEffect of Bed Diameter on the Hydrodynamics of Gas-Solid Fluidized Beds
Effect of scale on the hydrodynamics of gas-solid fluidized beds was investigated in two fluidized beds of 152 mm and 78 mm in diameter. Air at room temperature was used as the fluidizing gas in the bed of sand particles. The Radioactive Particle Tracking (RPT) technique was employed to obtain the instantaneous positions of the particles at every 20 ms of the experiments. These data were u...
متن کاملGas Mixing Simulation in a T-Shape Micro Channel Using The DSMC Method
Gas mixing in a T-shape micro mixer has been simulated using the Direct Simulation Monte Carlo (DSMC) method. It is considered that the adequate mixing occurs when the mass composition of the species, CO or N2, deviates below 1 % from their equilibrium composition. The mixing coefficient is defined as the ratio of the mixing length to the main channel’s height. As the inlet Kn increases, while ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 62 5 شماره
صفحات -
تاریخ انتشار 1982