Accuracy of the Polar S810i(TM) Heart Rate Monitor and the Sensewear Pro Armband(TM) to Estimate Energy Expenditure of Indoor Rowing Exercise in Overweight and Obese Individuals.
نویسندگان
چکیده
Accurately assessing the energy expenditure (EE) of different types of physical activity is important for exercise prescription in obese individuals. The aim of this study was to examine the accuracy of the Polar S810i Heart Rate Monitor and SenseWear Pro Armband (SWA) for estimating energy expenditure (EE) during indoor rowing versus indirect calorimetry (IC). 43 overweight and obese adults (16 men, 27 women, BMI = 31.2 ± 3.7) participated in the study. Within a week after a maximal incremental test on a rowing ergometer, EE was assessed with Polar S810i, SWA and IC during two different intensities of rowing exercises (at 50% VO2max and 70% VO2max) on a Concept II ergometer. Data were analyzed with Pearson's product moment correlations and repeated measures ANOVA. Post hoc multiple comparisons were performed using the Bonferroni test. Bland-Altman plots were created to assess the agreement between the EE estimates and IC measurements. At 50% VO2max, Polar S810i and SWA significantly overestimated EE by 0.5 ± 0.50 kcal·min(-1) (p < 0.001) and by 0.9 ± 0.92 kcal·min(-1) (p < 0.001), respectively. At 70% VO2max, no significant differences were found between the SWA and IC, and between Polar S810i and IC measurements. Bland-Altman plots showed good agreements between the measured EE and estimates by Polar S810i and SWA at 70% VO2max. At 50% VO2max, there was a poor agreement between SWA and IC measurements. There were high correlations among three methods at both intensities (r = 0.82 to r = 0.95). In conclusion, Polar S810i and SWA showed reasonable concordance with IC for measuring EE of the moderate intensity exercise but not the lower intensity exercise on indoor rowing in the participants of this study. Polar S810i and SWA might be useful to assess EE during indoor rowing for overweight and obese individuals who try to manage their body weight, but it is necessary to develop exercise and population specific algorithms to enhance the accuracy of SWA to estimate energy expenditure during various intensities of physical exercises. Key pointsPolar S810i and SWA when compared to the indirect calorimetry, provide reasonable estimates of energy expenditure on rowing ergometer at the moderate exercise intensity, but not at the low exercise intensity.The monitor of the Concept II Model D rowing ergometer significantly overestimated the energy expenditure during low and moderate intensity exercises. However there was a moderate correlation between EE estimates of this device and indirect calorimetry measurements.
منابع مشابه
Abstract -- The ability to accurately and reliably monitor physical activity and energy expenditure has emerged as a critical component to weight management and the prevention of lifestyle related health
The ability to accurately and reliably monitor physical activity and energy expenditure has emerged as a critical component to weight management and the prevention of lifestyle related health problems. Current methods and tools used by researchers, clinical practitioners, and individuals to assess physical activity and energy expenditure were reviewed and found to have practicality and accuracy...
متن کاملSenseWear Armband and Stroke: Validity of Energy Expenditure and Step Count Measurement during Walking
The purpose of this study was to test the validity of the SenseWear Pro Armband (SWA) for the measurement of energy expenditure (EE) and step count against a criterion in persons with stroke. Twelve participants with chronic stroke (mean age 64.2 ± 10.4 years; mean gait speed 0.67 ± 0.25 m/sec) completed two trials of a six-minute walk test, while wearing a SenseWear Armband (SWA) on each arm a...
متن کاملValidation of a Pre-Coded Food Diary Used among 60–80 Year Old Men: Comparison of Self-Reported Energy Intake with Objectively Recorded Energy Expenditure
OBJECTIVE To validate energy intake (EI) estimated from a pre-coded food diary (PFD) against energy expenditure (EE) measured with a valid physical activity monitor (SenseWear Pro3 Armband) and to evaluate whether misreporting was associated with overweight/obesity in a group of elderly men. METHODS Forty-seven healthy Norwegian men, 60-80 years old, completed the study. As this study was par...
متن کاملMonitoring Energy Expenditure Using a Multi-Sensor Device—Applications and Limitations of the SenseWear Armband in Athletic Populations
In order to monitor their energy requirements, athletes may desire to assess energy expenditure (EE) during training and competition. Recent technological advances and increased customer interest have created a market for wearable devices that measure physiological variables and bodily movement over prolonged time periods and convert this information into EE data. This mini-review provides an o...
متن کاملEvaluation of custom energy expenditure models for SenseWear armband in manual wheelchair users.
Physical activity monitors are increasingly used to help the general population lead a healthy lifestyle by keeping track of their daily physical activity (PA) and energy expenditure (EE). However, none of the commercially available activity monitors can accurately estimate PA and EE in people who use wheelchairs as their primary means of mobility. Researchers have recently developed custom EE ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 9 3 شماره
صفحات -
تاریخ انتشار 2010