Improved left ventricular relaxation during short-term right ventricular outflow tract compared to apical pacing.

نویسندگان

  • T M Kolettis
  • Z S Kyriakides
  • D Tsiapras
  • T Popov
  • I A Paraskevaides
  • D T Kremastinos
چکیده

STUDY OBJECTIVES Pacing-induced asynchrony may deteriorate left ventricular function; however, limited data exists in humans. The aim of our study was to compare left ventricular hemodynamics during short-term atrioventricular sequential pacing from the right ventricular apex and from the outflow tract of the right ventricle. DESIGN Three 5-min pacing intervals were applied in a random order, at a rate of 15 beats/min above the resting sinus rate. Atrioventricular sequential pacing from the two sites was compared with atrial pacing. During each pacing mode, left ventricular pressure was recorded, and cardiac output was calculated using Doppler echocardiography. SETTING Cardiac catheterization laboratory. PATIENTS Twenty patients (18 male, mean age 62 +/- 11 years) without structural heart disease were studied. RESULTS During atrial pacing, maximum negative first derivative of pressure (dp/dt) was 1,535 +/- 228 mm Hg/s; during pacing from the apex it decreased to 1,221 +/- 294 mm Hg/s (p = 0.0001), but was not significantly different during pacing from the outflow tract (1,431 +/- 435 mm Hg/s, p > 0.05). Isovolumic relaxation time constant (tau) during atrial pacing was 39.7 +/- 11.9 ms; during pacing from the apex, it increased to 47.9 +/- 14.0 (p = 0.001), but was not significantly different during pacing from the outflow tract (42.5 +/- 11.2, p > 0.05). Peak systolic pressure decreased significantly during atrioventricular sequential pacing from either site; however, it did not differ between the two sites. No differences in end-diastolic pressure, maximum positive dp/dt, or cardiac output could be demonstrated. CONCLUSION In patients with no structural heart disease, short-term right ventricular outflow tract pacing is associated with more favorable diastolic function, compared to right ventricular apical pacing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right Ventricular Outflow Tract Septal Pacing Is Superior to Right Ventricular Apical Pacing

BACKGROUND The effects of right ventricular apical pacing (RVAP) and right ventricular outflow tract (RVOT) septal pacing on atrial and ventricular electrophysiology have not been thoroughly compared. METHODS AND RESULTS To identify a more favorable pacing strategy with fewer adverse effects, 80 patients who had complete atrioventricular block with normal cardiac function and who were treated...

متن کامل

Radial left ventricular dyssynchrony by speckle tracking in apical versus non apical right ventricular pacing- evidence of dyssynchrony on medium term follow up.

INTRODUCTION To study effects of various sites of right ventricular pacing lead implantation on left ventricular function by 2-dimensional (2D) speckle tracking for radial strain and LV dyssynchrony. METHODS This was retrospective prospective study. Fifteen patients each with right ventricular (RV) apical (RV apex and apical septum) and non-apical (mid septal and low right ventricular outflow...

متن کامل

Alternate site pacing in patients at risk for heart failure.

Cardiac pacing from the right ventricular apex is the most common site of cardiac pacing. During the last decade, several studies demonstrated the harmful effects of the iatrogenic left bundle branch block, which is observed in cardiac pacing from the right ventricular apex. These observations led to an interest in alternative right ventricular pacing sites aiming to achieve a more "physiologic...

متن کامل

Acute Impact of Pacing at Different Cardiac Sites on Left Ventricular Rotation and Twist in Dogs

OBJECTIVES We evaluated the acute impact of different cardiac pacing sites on two-dimensional speckle-tracking echocardiography (STE) derived left ventricular (LV) rotation and twist in healthy dogs. METHODS Twelve dogs were used in this study. The steerable pacing electrodes were positioned into right heart through the superior or inferior vena cava, into LV through aorta across the aortic v...

متن کامل

Acute effects of dual-chamber pacing on the left ventricular systolic function and relaxation in patients with advanced AV block and sick sinus syndrome.

BACKGROUND Abnormal activation of the ventricles via right ventricular apical pacing deteriorates cardiac function, which may explain the increased mortality of patients with congestive heart failure receiving permanent pacemakers. We hypothesized that pacing at alternative sites may cause less detrimental effects on the cardiac function. METHODS Five symptomatic patients with either advanced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 117 1  شماره 

صفحات  -

تاریخ انتشار 2000