Further Development in Characterization of Radioactive Waste Drums by Non Destructive Gamma Spectrometry at GRR-1

نویسندگان

  • A. SAVIDOU
  • F. TZIKA
  • I. E. STAMATELATOS
چکیده

A non destructive technique based on gamma spectrometry and application of the Monte Carlo method for detector efficiency calibration, was used to assay radioactive content waste drums. Exploranium GR-130 miniSPEC portable gamma ray spectrometer was used to externally monitor radioactive waste drums containing ion exchange resin waste from the water demineralization system of GRR-1 open pool-type research reactor facility at NCSR “Demokritos”. Detection efficiency was predicted by Monte Carlo simulation performed with the MCNP-4C2 code and cross-section data from the ENDF-VI-b library. The code was used to perform numerical simulations taking into consideration the energy of the gamma ray emitter, the matrix material, the detector characteristics, the geometric configuration employed, the size of the drum, and the wall material and thickness of the drum. Efficiency curves in the energy range 60 to 1500 keV were predicted assuming a homogeneous distribution of the source activity within the matrix material. A relative error of less than 5% was achieved in all simulated cases. Satisfactory agreement was observed by comparing the results of the non destructive method against analytical results of samples obtained from 25drums. Moreover the MCNP model was used to examine the effect of inhomogeneities, on the accuracy of the technique and estimate the measurement bias. A technique to predict such inhomogeneities by measurements at different source to detector positions was examined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Radioactive Waste Drums by Non Destructive Gamma Spectrometry

Assay of the radioactive content of waste drums is important for inventory and waste disposal purposes. The sampling of the drum content is a difficult, time and labor consuming procedure, involving special radiation protection considerations. On the other hand the characterization of waste drums containing radioactivity by measuring the drum as a whole (without opening) offers overall simplici...

متن کامل

Efficiency Calibration Studies for Gamma Spectrometric Systems: the Influence of Different Parameters

The radioactive waste containers, containing different radioactive materials, have to be characterized before their final disposal. Destructive methods, although being the most precise, are also the most expensive and not the easiest ones from the radioprotection point of view. In this situation, high resolution gamma spectrometry proved to be a reliable method for the non destructive assay met...

متن کامل

The Response Function of Isocart (ortec) Gamma-ray Spectrometry System Using Monte Carlo Simulations

The routine operation and maintenance of nuclear facilities generate quantities of radioactive material in many different matrices that are packed in many different sized containers. The waste is often packaged in large containers, such as 220 l drums, because process operators find drums more economical to handle than small containers. Based on regulations, the radioactivity and the radionucli...

متن کامل

The Role of Mathematical Methods in Efficiency Calibration and Uncertainty Estimation in Gamma Based Non-Destructive Assay - 12311

Mathematical methods are being increasingly employed in the efficiency calibration of gamma based systems for non-destructive assay (NDA) of radioactive waste and for the estimation of the Total Measurement Uncertainty (TMU). Recently, ASTM (American Society for Testing and Materials) released a standard guide for use of modeling passive gamma measurements. This is a testimony to the common use...

متن کامل

HPGe and Scintillation Detectors Comparisons on Waste Drums Radioactivity Measurement

Two measurement systems, one being comprised of three HPGe detectors and the other being a 4π measurement system of the assembly of 10 sets of scintillation detectors, were compared for their measurement performance in operations of radioactive waste drum radioactivity measurement and clearance and release operation of decommissioning. The system features of the former were high costs, capable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007